Skip to content
Projects
Groups
Snippets
Help
Loading...
Help
Support
Keyboard shortcuts
?
Submit feedback
Contribute to GitLab
Sign in / Register
Toggle navigation
osie
Project overview
Project overview
Details
Activity
Releases
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Issues
0
Issues
0
List
Boards
Labels
Milestones
Merge Requests
0
Merge Requests
0
CI / CD
CI / CD
Pipelines
Jobs
Schedules
Analytics
Analytics
CI / CD
Repository
Value Stream
Wiki
Wiki
Snippets
Snippets
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Create a new issue
Jobs
Commits
Issue Boards
Open sidebar
Nikola Balog
osie
Commits
ebe760bd
Commit
ebe760bd
authored
Jul 12, 2023
by
Ivan Tyagov
Browse files
Options
Browse Files
Download
Plain Diff
parents
cdd9c8b8
92340f80
Changes
9
Show whitespace changes
Inline
Side-by-side
Showing
9 changed files
with
364 additions
and
0 deletions
+364
-0
Beremiz/beremiz_oi_sensor_tutorial/beremiz.xml
Beremiz/beremiz_oi_sensor_tutorial/beremiz.xml
+4
-0
Beremiz/beremiz_oi_sensor_tutorial/opcua_0@opcua/baseconfnode.xml
...beremiz_oi_sensor_tutorial/opcua_0@opcua/baseconfnode.xml
+2
-0
Beremiz/beremiz_oi_sensor_tutorial/opcua_0@opcua/confnode.xml
...miz/beremiz_oi_sensor_tutorial/opcua_0@opcua/confnode.xml
+4
-0
Beremiz/beremiz_oi_sensor_tutorial/opcua_0@opcua/selected.csv
...miz/beremiz_oi_sensor_tutorial/opcua_0@opcua/selected.csv
+2
-0
Beremiz/beremiz_oi_sensor_tutorial/opcua_1@opcua/baseconfnode.xml
...beremiz_oi_sensor_tutorial/opcua_1@opcua/baseconfnode.xml
+2
-0
Beremiz/beremiz_oi_sensor_tutorial/opcua_1@opcua/confnode.xml
...miz/beremiz_oi_sensor_tutorial/opcua_1@opcua/confnode.xml
+2
-0
Beremiz/beremiz_oi_sensor_tutorial/opcua_1@opcua/selected.csv
...miz/beremiz_oi_sensor_tutorial/opcua_1@opcua/selected.csv
+4
-0
Beremiz/beremiz_oi_sensor_tutorial/plc.xml
Beremiz/beremiz_oi_sensor_tutorial/plc.xml
+235
-0
oi-sensor/opcua-oi-server.py
oi-sensor/opcua-oi-server.py
+109
-0
No files found.
Beremiz/beremiz_oi_sensor_tutorial/beremiz.xml
0 → 100644
View file @
ebe760bd
<?xml version='1.0' encoding='utf-8'?>
<BeremizRoot
xmlns:xsd=
"http://www.w3.org/2001/XMLSchema"
URI_location=
"LOCAL://"
>
<TargetType/>
</BeremizRoot>
Beremiz/beremiz_oi_sensor_tutorial/opcua_0@opcua/baseconfnode.xml
0 → 100644
View file @
ebe760bd
<?xml version='1.0' encoding='utf-8'?>
<BaseParams
xmlns:xsd=
"http://www.w3.org/2001/XMLSchema"
IEC_Channel=
"1"
Name=
"opcua_0"
/>
Beremiz/beremiz_oi_sensor_tutorial/opcua_0@opcua/confnode.xml
0 → 100644
View file @
ebe760bd
<?xml version='1.0' encoding='utf-8'?>
<OPCUAClient
xmlns:xsd=
"http://www.w3.org/2001/XMLSchema"
Server_URI=
"opc.tcp://192.168.0.118:4840"
>
<AuthType/>
</OPCUAClient>
Beremiz/beremiz_oi_sensor_tutorial/opcua_0@opcua/selected.csv
0 → 100644
View file @
ebe760bd
input,shape,2,int,2,Double,2
output,shape,2,int,2,Double,2
Beremiz/beremiz_oi_sensor_tutorial/opcua_1@opcua/baseconfnode.xml
0 → 100644
View file @
ebe760bd
<?xml version='1.0' encoding='utf-8'?>
<BaseParams
xmlns:xsd=
"http://www.w3.org/2001/XMLSchema"
IEC_Channel=
"0"
Name=
"opcua_1"
/>
Beremiz/beremiz_oi_sensor_tutorial/opcua_1@opcua/confnode.xml
0 → 100644
View file @
ebe760bd
<?xml version='1.0' encoding='utf-8'?>
<OPCUAClient
xmlns:xsd=
"http://www.w3.org/2001/XMLSchema"
Server_URI=
"opc.tcp://192.168.0.135:4840"
/>
Beremiz/beremiz_oi_sensor_tutorial/opcua_1@opcua/selected.csv
0 → 100644
View file @
ebe760bd
input,I2C0 / Relay 0,1,str,i2c0.relay0,Int32,0
input,I2C0 / Relay 1,1,str,i2c0.relay1,Int32,1
output,I2C0 / Relay 0,1,str,i2c0.relay0,Int32,0
output,I2C0 / Relay 1,1,str,i2c0.relay1,Int32,1
Beremiz/beremiz_oi_sensor_tutorial/plc.xml
0 → 100644
View file @
ebe760bd
<?xml version='1.0' encoding='utf-8'?>
<project
xmlns:ns1=
"http://www.plcopen.org/xml/tc6_0201"
xmlns:xhtml=
"http://www.w3.org/1999/xhtml"
xmlns:xsd=
"http://www.w3.org/2001/XMLSchema"
xmlns=
"http://www.plcopen.org/xml/tc6_0201"
>
<fileHeader
companyName=
"Unknown"
productName=
"Unnamed"
productVersion=
"1"
creationDateTime=
"2021-05-14T14:33:11"
/>
<contentHeader
name=
"Counter (OSIE)"
modificationDateTime=
"2023-07-12T15:09:32"
>
<coordinateInfo>
<fbd>
<scaling
x=
"0"
y=
"0"
/>
</fbd>
<ld>
<scaling
x=
"0"
y=
"0"
/>
</ld>
<sfc>
<scaling
x=
"0"
y=
"0"
/>
</sfc>
</coordinateInfo>
</contentHeader>
<types>
<dataTypes/>
<pous>
<pou
name=
"plc_prg"
pouType=
"program"
>
<interface>
<inputVars>
<variable
name=
"Reset"
>
<type>
<BOOL/>
</type>
</variable>
</inputVars>
<outputVars>
<variable
name=
"Cnt0"
>
<type>
<INT/>
</type>
</variable>
<variable
name=
"Cnt1"
>
<type>
<INT/>
</type>
</variable>
</outputVars>
<localVars>
<variable
name=
"CounterST0"
>
<type>
<derived
name=
"CounterST"
/>
</type>
</variable>
</localVars>
</interface>
<body>
<FBD>
<comment
localId=
"1"
height=
"143"
width=
"201"
>
<position
x=
"566"
y=
"75"
/>
<content>
<xhtml:p>
<![CDATA[Test Ivan: this PLC will switch ON / OFF attached over modbus relays {0..3} of a Lime2 coupler.]]>
</xhtml:p>
</content>
</comment>
<block
localId=
"2"
typeName=
"CounterST"
instanceName=
"CounterST0"
executionOrderId=
"0"
height=
"109"
width=
"99"
>
<position
x=
"288"
y=
"192"
/>
<inputVariables>
<variable
formalParameter=
"Reset"
>
<connectionPointIn>
<relPosition
x=
"0"
y=
"42"
/>
<connection
refLocalId=
"3"
>
<position
x=
"288"
y=
"234"
/>
<position
x=
"258"
y=
"234"
/>
<position
x=
"258"
y=
"218"
/>
<position
x=
"231"
y=
"218"
/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable
formalParameter=
"Out1"
>
<connectionPointOut>
<relPosition
x=
"99"
y=
"42"
/>
</connectionPointOut>
</variable>
<variable
formalParameter=
"Out0"
>
<connectionPointOut>
<relPosition
x=
"99"
y=
"86"
/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<inVariable
localId=
"3"
executionOrderId=
"0"
height=
"25"
width=
"50"
negated=
"false"
>
<position
x=
"181"
y=
"206"
/>
<connectionPointOut>
<relPosition
x=
"50"
y=
"12"
/>
</connectionPointOut>
<expression>
Reset
</expression>
</inVariable>
<outVariable
localId=
"4"
executionOrderId=
"0"
height=
"25"
width=
"42"
negated=
"false"
>
<position
x=
"433"
y=
"266"
/>
<connectionPointIn>
<relPosition
x=
"0"
y=
"12"
/>
<connection
refLocalId=
"2"
formalParameter=
"Out0"
>
<position
x=
"433"
y=
"278"
/>
<position
x=
"387"
y=
"278"
/>
</connection>
</connectionPointIn>
<expression>
Cnt0
</expression>
</outVariable>
<outVariable
localId=
"6"
executionOrderId=
"0"
height=
"25"
width=
"42"
negated=
"false"
>
<position
x=
"435"
y=
"222"
/>
<connectionPointIn>
<relPosition
x=
"0"
y=
"12"
/>
<connection
refLocalId=
"2"
formalParameter=
"Out1"
>
<position
x=
"435"
y=
"234"
/>
<position
x=
"387"
y=
"234"
/>
</connection>
</connectionPointIn>
<expression>
Cnt1
</expression>
</outVariable>
</FBD>
</body>
</pou>
<pou
name=
"CounterST"
pouType=
"functionBlock"
>
<interface>
<inputVars>
<variable
name=
"Reset"
>
<type>
<BOOL/>
</type>
</variable>
</inputVars>
<outputVars>
<variable
name=
"Out1"
>
<type>
<INT/>
</type>
</variable>
<variable
name=
"Out0"
>
<type>
<INT/>
</type>
</variable>
</outputVars>
<localVars>
<variable
name=
"Cnt0"
>
<type>
<INT/>
</type>
</variable>
</localVars>
<externalVars>
<variable
name=
"ResetCounterValue"
>
<type>
<INT/>
</type>
</variable>
<variable
name=
"OpticalShape"
>
<type>
<LREAL/>
</type>
</variable>
<variable
name=
"Relay0"
>
<type>
<DINT/>
</type>
</variable>
<variable
name=
"Relay1"
>
<type>
<DINT/>
</type>
</variable>
</externalVars>
</interface>
<body>
<ST>
<xhtml:p>
<![CDATA[(* this will always switch on relay0 which controls conveyor line*)
Relay0 := 1;
IF OpticalShape=2.0 THEN
(* a rectangle was recognized thus switch ON air valve *)
Relay1 := 1;
END_IF;
IF OpticalShape=0.0 OR OpticalShape=1.0 OR OpticalShape=3.0 THEN
(* a circle / triangle or nothing was recognized thus switch OFF air valve *)
Relay1 := 0;
END_IF;
]]>
</xhtml:p>
</ST>
</body>
</pou>
</pous>
</types>
<instances>
<configurations>
<configuration
name=
"config"
>
<resource
name=
"resource1"
>
<task
name=
"task0"
priority=
"0"
interval=
"T#50ms"
>
<pouInstance
name=
"instance0"
typeName=
"plc_prg"
/>
</task>
</resource>
<globalVars>
<variable
name=
"ResetCounterValue"
>
<type>
<INT/>
</type>
<initialValue>
<simpleValue
value=
"0"
/>
</initialValue>
</variable>
<variable
name=
"OpticalShape"
address=
"%IL1.2"
>
<type>
<LREAL/>
</type>
<documentation>
<xhtml:p>
<![CDATA[OPC UA optical shape sensor]]>
</xhtml:p>
</documentation>
</variable>
<variable
name=
"Relay0"
address=
"%QD0.0"
>
<type>
<DINT/>
</type>
<documentation>
<xhtml:p>
<![CDATA[relay 0 (drive motor)]]>
</xhtml:p>
</documentation>
</variable>
<variable
name=
"Relay1"
address=
"%QD0.1"
>
<type>
<DINT/>
</type>
<documentation>
<xhtml:p>
<![CDATA[relay 0 (air valve)]]>
</xhtml:p>
</documentation>
</variable>
</globalVars>
</configuration>
</configurations>
</instances>
</project>
oi-sensor/opcua-oi-server.py
0 → 100644
View file @
ebe760bd
#!/usr/bin/python
"""
Basic (POC) OPC UA shape detection sensor using opencv libraryś countours detection.
Exposes a default OPC UA shape detection profile where:
0.0 - nothing detected
1.0 - triangle
2.0 - rectangle
3.0 - circle
Based on this classification any PLC can integrate this Optical Inspection and implement
additional logic.
"""
import
cv2
import
numpy
as
np
import
asyncio
import
logging
from
asyncua
import
Server
def
nothing
(
x
):
# any operation
pass
async
def
main
():
_logger
=
logging
.
getLogger
(
__name__
)
# setup our server
server
=
Server
()
await
server
.
init
()
server
.
set_endpoint
(
"opc.tcp://0.0.0.0:4840/freeopcua/server/"
)
# set up our own namespace, not really necessary but should as spec
uri
=
"http://examples.freeopcua.github.io"
idx
=
await
server
.
register_namespace
(
uri
)
# populating our address space
myobj
=
await
server
.
nodes
.
objects
.
add_object
(
idx
,
"OpticalInspection"
)
myvar
=
await
myobj
.
add_variable
(
idx
,
"shape"
,
0.0
)
await
myvar
.
set_writable
()
# init camera
cap
=
cv2
.
VideoCapture
(
0
)
cv2
.
namedWindow
(
"Trackbars"
)
cv2
.
createTrackbar
(
"L-H"
,
"Trackbars"
,
0
,
180
,
nothing
)
cv2
.
createTrackbar
(
"L-S"
,
"Trackbars"
,
0
,
255
,
nothing
)
cv2
.
createTrackbar
(
"L-V"
,
"Trackbars"
,
3
,
255
,
nothing
)
cv2
.
createTrackbar
(
"U-H"
,
"Trackbars"
,
39
,
180
,
nothing
)
cv2
.
createTrackbar
(
"U-S"
,
"Trackbars"
,
155
,
255
,
nothing
)
cv2
.
createTrackbar
(
"U-V"
,
"Trackbars"
,
148
,
255
,
nothing
)
font
=
cv2
.
FONT_HERSHEY_COMPLEX
_logger
.
info
(
"Starting server!"
)
async
with
server
:
while
True
:
# XXX: find out why we need to sleep (otherwise OPC UA server stops work)
await
asyncio
.
sleep
(
0.0001
)
# read and process camera
_
,
frame
=
cap
.
read
()
hsv
=
cv2
.
cvtColor
(
frame
,
cv2
.
COLOR_BGR2HSV
)
l_h
=
cv2
.
getTrackbarPos
(
"L-H"
,
"Trackbars"
)
l_s
=
cv2
.
getTrackbarPos
(
"L-S"
,
"Trackbars"
)
l_v
=
cv2
.
getTrackbarPos
(
"L-V"
,
"Trackbars"
)
u_h
=
cv2
.
getTrackbarPos
(
"U-H"
,
"Trackbars"
)
u_s
=
cv2
.
getTrackbarPos
(
"U-S"
,
"Trackbars"
)
u_v
=
cv2
.
getTrackbarPos
(
"U-V"
,
"Trackbars"
)
lower_red
=
np
.
array
([
l_h
,
l_s
,
l_v
])
upper_red
=
np
.
array
([
u_h
,
u_s
,
u_v
])
mask
=
cv2
.
inRange
(
hsv
,
lower_red
,
upper_red
)
kernel
=
np
.
ones
((
5
,
5
),
np
.
uint8
)
mask
=
cv2
.
erode
(
mask
,
kernel
)
# Contours detection
contours
,
_
=
cv2
.
findContours
(
mask
,
cv2
.
RETR_TREE
,
cv2
.
CHAIN_APPROX_SIMPLE
)
for
cnt
in
contours
:
area
=
cv2
.
contourArea
(
cnt
)
approx
=
cv2
.
approxPolyDP
(
cnt
,
0.02
*
cv2
.
arcLength
(
cnt
,
True
),
True
)
x
=
approx
.
ravel
()[
0
]
y
=
approx
.
ravel
()[
1
]
if
area
>
400
:
cv2
.
drawContours
(
frame
,
[
approx
],
0
,
(
0
,
0
,
0
),
5
)
if
len
(
approx
)
==
3
:
cv2
.
putText
(
frame
,
"Triangle"
,
(
x
,
y
),
font
,
1
,
(
0
,
0
,
0
))
await
myvar
.
write_value
(
1.0
)
#_logger.info("Triangle")
elif
len
(
approx
)
==
4
:
cv2
.
putText
(
frame
,
"Rectangle"
,
(
x
,
y
),
font
,
1
,
(
0
,
0
,
0
))
await
myvar
.
write_value
(
2.0
)
#_logger.info("Rectangle")
elif
7
<
len
(
approx
)
<
20
:
cv2
.
putText
(
frame
,
"Circle"
,
(
x
,
y
),
font
,
1
,
(
0
,
0
,
0
))
await
myvar
.
write_value
(
3.0
)
#_logger.info("Circle")
else
:
await
myvar
.
write_value
(
0.0
)
cv2
.
imshow
(
"Frame"
,
frame
)
cv2
.
imshow
(
"Mask"
,
mask
)
key
=
cv2
.
waitKey
(
1
)
if
key
==
27
:
break
if
__name__
==
"__main__"
:
logging
.
basicConfig
(
level
=
logging
.
ERROR
)
asyncio
.
run
(
main
(),
debug
=
True
)
Write
Preview
Markdown
is supported
0%
Try again
or
attach a new file
Attach a file
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Cancel
Please
register
or
sign in
to comment