Skip to content
Projects
Groups
Snippets
Help
Loading...
Help
Support
Keyboard shortcuts
?
Submit feedback
Contribute to GitLab
Sign in / Register
Toggle navigation
P
proview
Project overview
Project overview
Details
Activity
Releases
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Issues
0
Issues
0
List
Boards
Labels
Milestones
Merge Requests
0
Merge Requests
0
CI / CD
CI / CD
Pipelines
Jobs
Schedules
Analytics
Analytics
CI / CD
Repository
Value Stream
Wiki
Wiki
Snippets
Snippets
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Create a new issue
Jobs
Commits
Issue Boards
Open sidebar
Esteban Blanc
proview
Commits
e01bb94c
Commit
e01bb94c
authored
Feb 03, 2014
by
Claes Sjofors
Browse files
Options
Browse Files
Download
Email Patches
Plain Diff
Frequency converter object, DSUp TimerTime set
parent
44d9a058
Changes
2
Hide whitespace changes
Inline
Side-by-side
Showing
2 changed files
with
41 additions
and
11 deletions
+41
-11
bcomp/wbl/bcomp/src/basecomponent.wb_load
bcomp/wbl/bcomp/src/basecomponent.wb_load
+33
-9
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
+8
-2
No files found.
bcomp/wbl/bcomp/src/basecomponent.wb_load
View file @
e01bb94c
...
...
@@ -128216,7 +128216,7 @@ Err (error) = err"
EndObject
EndObject
Object Template BaseFcPPO5 2192801792 01-JAN-1970 01:00:00.00
Body RtBody
18-MAR-2010 16:25:53.37
Body RtBody
27-JAN-2014 10:34:07.94
Attr Specification = "Frequency converter with Profibus PPO5 protocol"
Attr InIdPar.Description = "Parameter Identification, from converter"
Attr InIdPar.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO5IoModule.I_ID"
...
...
@@ -128280,6 +128280,7 @@ Err (error) = err"
Attr AlarmLocalMod.MoreText = ""
Attr AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO5-Template"
Attr AlarmLocalMod.CtrlPosition = 1
Attr AlarmLocalMod.TimerTime = 3.000000e+00
Attr AlarmLocalMod.LockAttribute = 1
Attr AlarmTripped.DetectOn = 1
Attr AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -128298,6 +128299,7 @@ Err (error) = err"
Attr AlarmWarning.MoreText = ""
Attr AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO5-Template"
Attr AlarmWarning.CtrlPosition = 1
Attr AlarmWarning.TimerTime = 5.000000e+00
Attr AlarmWarning.LockAttribute = 1
Attr AlarmError.DetectOn = 1
Attr AlarmError.DetectText = "Frequency converter error"
...
...
@@ -128316,6 +128318,7 @@ Err (error) = err"
Attr AlarmConnection.MoreText = ""
Attr AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO5-Template"
Attr AlarmConnection.CtrlPosition = 1
Attr AlarmConnection.TimerTime = 3.000000e+00
Attr AlarmConnection.LockAttribute = 1
Attr DefTrend = "BaseComponent:Class-BaseFcPPO5-Template.PlotGroup"
Attr TrendActSpeed.Multiple = 1
...
...
@@ -137853,7 +137856,7 @@ if Op reset converter."
EndObject
EndObject
Object Template BaseFcPPO5MotorAggr 2194112512 01-JAN-1970 01:00:00.00
Body RtBody 2
9-NOV-2013 16:27:25.18
Body RtBody 2
7-JAN-2014 10:35:50.25
Attr AlarmToOften.DetectOn = 1
Attr AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr AlarmToOften.EventType = 64
...
...
@@ -137958,6 +137961,7 @@ if Op reset converter."
Attr FrequencyConverter.AlarmLocalMod.MoreText = ""
Attr FrequencyConverter.AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO5MotorAggr-Template.FrequencyConverter"
Attr FrequencyConverter.AlarmLocalMod.CtrlPosition = 1
Attr FrequencyConverter.AlarmLocalMod.TimerTime = 3.000000e+00
Attr FrequencyConverter.AlarmLocalMod.LockAttribute = 1
Attr FrequencyConverter.AlarmTripped.DetectOn = 1
Attr FrequencyConverter.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -137976,6 +137980,7 @@ if Op reset converter."
Attr FrequencyConverter.AlarmWarning.MoreText = ""
Attr FrequencyConverter.AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO5MotorAggr-Template.FrequencyConverter"
Attr FrequencyConverter.AlarmWarning.CtrlPosition = 1
Attr FrequencyConverter.AlarmWarning.TimerTime = 5.000000e+00
Attr FrequencyConverter.AlarmWarning.LockAttribute = 1
Attr FrequencyConverter.AlarmError.DetectOn = 1
Attr FrequencyConverter.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -137994,6 +137999,7 @@ if Op reset converter."
Attr FrequencyConverter.AlarmConnection.MoreText = ""
Attr FrequencyConverter.AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO5MotorAggr-Template.FrequencyConverter"
Attr FrequencyConverter.AlarmConnection.CtrlPosition = 1
Attr FrequencyConverter.AlarmConnection.TimerTime = 3.000000e+00
Attr FrequencyConverter.AlarmConnection.LockAttribute = 1
Attr FrequencyConverter.DefTrend = "BaseComponent:Class-BaseFcPPO5MotorAggr-Template.FrequencyConverter.PlotGroup"
Attr FrequencyConverter.TrendActSpeed.Multiple = 1
...
...
@@ -147720,10 +147726,10 @@ Fc PPO5 Motor Aggregate
Attr Flags = 131080
Attr TypeRef = "BaseComponent:Class-BaseFan"
EndBody
EndObject
EndObject
EndObject
Object Template BaseFcPPO5FanAggr 2194898944 01-JAN-1970 01:00:00.00
Body RtBody 2
3-MAR-2010 15:50:38.74
Body RtBody 2
7-JAN-2014 10:36:34.47
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
...
...
@@ -147828,6 +147834,7 @@ Fc PPO5 Motor Aggregate
Attr Super.FrequencyConverter.AlarmLocalMod.MoreText = ""
Attr Super.FrequencyConverter.AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO5FanAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmLocalMod.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmLocalMod.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmLocalMod.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectOn = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -147846,6 +147853,7 @@ Fc PPO5 Motor Aggregate
Attr Super.FrequencyConverter.AlarmWarning.MoreText = ""
Attr Super.FrequencyConverter.AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO5FanAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmWarning.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmWarning.TimerTime = 5.000000e+00
Attr Super.FrequencyConverter.AlarmWarning.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmError.DetectOn = 1
Attr Super.FrequencyConverter.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -147864,6 +147872,7 @@ Fc PPO5 Motor Aggregate
Attr Super.FrequencyConverter.AlarmConnection.MoreText = ""
Attr Super.FrequencyConverter.AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO5FanAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmConnection.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmConnection.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmConnection.LockAttribute = 1
Attr Super.FrequencyConverter.DefTrend = "BaseComponent:Class-BaseFcPPO5FanAggr-Template.Super.FrequencyConverter.PlotGroup"
Attr Super.FrequencyConverter.TrendActSpeed.Multiple = 1
...
...
@@ -148099,7 +148108,7 @@ Fc PPO5 Motor Aggregate
EndObject
EndObject
Object Template BaseFcPPO5PumpAggr 2195161088 01-JAN-1970 01:00:00.00
Body RtBody 2
3-MAR-2010 15:51:00.97
Body RtBody 2
7-JAN-2014 10:37:03.06
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
...
...
@@ -148204,6 +148213,7 @@ Fc PPO5 Motor Aggregate
Attr Super.FrequencyConverter.AlarmLocalMod.MoreText = ""
Attr Super.FrequencyConverter.AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO5PumpAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmLocalMod.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmLocalMod.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmLocalMod.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectOn = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -148222,6 +148232,7 @@ Fc PPO5 Motor Aggregate
Attr Super.FrequencyConverter.AlarmWarning.MoreText = ""
Attr Super.FrequencyConverter.AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO5PumpAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmWarning.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmWarning.TimerTime = 5.000000e+00
Attr Super.FrequencyConverter.AlarmWarning.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmError.DetectOn = 1
Attr Super.FrequencyConverter.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -148240,6 +148251,7 @@ Fc PPO5 Motor Aggregate
Attr Super.FrequencyConverter.AlarmConnection.MoreText = ""
Attr Super.FrequencyConverter.AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO5PumpAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmConnection.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmConnection.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmConnection.LockAttribute = 1
Attr Super.FrequencyConverter.DefTrend = "BaseComponent:Class-BaseFcPPO5PumpAggr-Template.Super.FrequencyConverter.PlotGroup"
Attr Super.FrequencyConverter.TrendActSpeed.Multiple = 1
...
...
@@ -148944,7 +148956,7 @@ Fc PPO5 Motor Aggregate
EndObject
EndObject
Object Template BaseFcPPO3 2195423232 01-JAN-1970 01:00:00.00
Body RtBody
18-MAR-2010 16:25:40.58
Body RtBody
27-JAN-2014 10:33:49.73
Attr Specification = "Frequency converter with Profibus PPO3 protocol"
Attr StatusWordSW.Description = "Status Word, from converter"
Attr StatusWordSW.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO3IoModule.I_SW"
...
...
@@ -148967,6 +148979,7 @@ Fc PPO5 Motor Aggregate
Attr AlarmLocalMod.MoreText = ""
Attr AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO3-Template"
Attr AlarmLocalMod.CtrlPosition = 1
Attr AlarmLocalMod.TimerTime = 3.000000e+00
Attr AlarmLocalMod.LockAttribute = 1
Attr AlarmTripped.DetectOn = 1
Attr AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -148985,6 +148998,7 @@ Fc PPO5 Motor Aggregate
Attr AlarmWarning.MoreText = ""
Attr AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO3-Template"
Attr AlarmWarning.CtrlPosition = 1
Attr AlarmWarning.TimerTime = 5.000000e+00
Attr AlarmWarning.LockAttribute = 1
Attr AlarmError.DetectOn = 1
Attr AlarmError.DetectText = "Frequency converter error"
...
...
@@ -149003,6 +149017,7 @@ Fc PPO5 Motor Aggregate
Attr AlarmConnection.MoreText = ""
Attr AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO3-Template"
Attr AlarmConnection.CtrlPosition = 1
Attr AlarmConnection.TimerTime = 3.000000e+00
Attr AlarmConnection.LockAttribute = 1
Attr DefTrend = "BaseComponent:Class-BaseFcPPO3-Template.PlotGroup"
Attr TrendActSpeed.Multiple = 1
...
...
@@ -156738,7 +156753,7 @@ if Op reset converter."
EndObject
EndObject
Object Template BaseFcPPO3MotorAggr 2196471808 01-JAN-1970 01:00:00.00
Body RtBody 2
9-NOV-2013 16:36:50.47
Body RtBody 2
7-JAN-2014 10:37:30.49
Attr AlarmToOften.DetectOn = 1
Attr AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr AlarmToOften.EventType = 64
...
...
@@ -156807,6 +156822,7 @@ if Op reset converter."
Attr FrequencyConverter.AlarmLocalMod.MoreText = ""
Attr FrequencyConverter.AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO3MotorAggr-Template.FrequencyConverter"
Attr FrequencyConverter.AlarmLocalMod.CtrlPosition = 1
Attr FrequencyConverter.AlarmLocalMod.TimerTime = 3.000000e+00
Attr FrequencyConverter.AlarmLocalMod.LockAttribute = 1
Attr FrequencyConverter.AlarmTripped.DetectOn = 1
Attr FrequencyConverter.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -156825,6 +156841,7 @@ if Op reset converter."
Attr FrequencyConverter.AlarmWarning.MoreText = ""
Attr FrequencyConverter.AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO3MotorAggr-Template.FrequencyConverter"
Attr FrequencyConverter.AlarmWarning.CtrlPosition = 1
Attr FrequencyConverter.AlarmWarning.TimerTime = 5.000000e+00
Attr FrequencyConverter.AlarmWarning.LockAttribute = 1
Attr FrequencyConverter.AlarmError.DetectOn = 1
Attr FrequencyConverter.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -156843,6 +156860,7 @@ if Op reset converter."
Attr FrequencyConverter.AlarmConnection.MoreText = ""
Attr FrequencyConverter.AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO3MotorAggr-Template.FrequencyConverter"
Attr FrequencyConverter.AlarmConnection.CtrlPosition = 1
Attr FrequencyConverter.AlarmConnection.TimerTime = 3.000000e+00
Attr FrequencyConverter.AlarmConnection.LockAttribute = 1
Attr FrequencyConverter.DefTrend = "BaseComponent:Class-BaseFcPPO3MotorAggr-Template.FrequencyConverter.PlotGroup"
Attr FrequencyConverter.TrendActSpeed.Multiple = 1
...
...
@@ -166561,7 +166579,7 @@ Fc PPO3 Motor Aggregate
EndObject
EndObject
Object Template BaseFcPPO3FanAggr 2197258240 01-JAN-1970 01:00:00.00
Body RtBody 2
3-MAR-2010 15:52:00.39
Body RtBody 2
7-JAN-2014 10:37:54.48
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
...
...
@@ -166630,6 +166648,7 @@ Fc PPO3 Motor Aggregate
Attr Super.FrequencyConverter.AlarmLocalMod.MoreText = ""
Attr Super.FrequencyConverter.AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO3FanAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmLocalMod.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmLocalMod.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmLocalMod.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectOn = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -166648,6 +166667,7 @@ Fc PPO3 Motor Aggregate
Attr Super.FrequencyConverter.AlarmWarning.MoreText = ""
Attr Super.FrequencyConverter.AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO3FanAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmWarning.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmWarning.TimerTime = 5.000000e+00
Attr Super.FrequencyConverter.AlarmWarning.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmError.DetectOn = 1
Attr Super.FrequencyConverter.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -166666,6 +166686,7 @@ Fc PPO3 Motor Aggregate
Attr Super.FrequencyConverter.AlarmConnection.MoreText = ""
Attr Super.FrequencyConverter.AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO3FanAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmConnection.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmConnection.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmConnection.LockAttribute = 1
Attr Super.FrequencyConverter.DefTrend = "BaseComponent:Class-BaseFcPPO3FanAggr-Template.Super.FrequencyConverter.PlotGroup"
Attr Super.FrequencyConverter.TrendActSpeed.Multiple = 1
...
...
@@ -166885,7 +166906,7 @@ Fc PPO3 Motor Aggregate
EndObject
EndObject
Object Template BaseFcPPO3PumpAggr 2197520384 01-JAN-1970 01:00:00.00
Body RtBody 2
3-MAR-2010 15:52:17.67
Body RtBody 2
7-JAN-2014 10:38:27.25
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
...
...
@@ -166954,6 +166975,7 @@ Fc PPO3 Motor Aggregate
Attr Super.FrequencyConverter.AlarmLocalMod.MoreText = ""
Attr Super.FrequencyConverter.AlarmLocalMod.Attribute = "BaseComponent:Class-BaseFcPPO3PumpAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmLocalMod.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmLocalMod.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmLocalMod.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectOn = 1
Attr Super.FrequencyConverter.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -166972,6 +166994,7 @@ Fc PPO3 Motor Aggregate
Attr Super.FrequencyConverter.AlarmWarning.MoreText = ""
Attr Super.FrequencyConverter.AlarmWarning.Attribute = "BaseComponent:Class-BaseFcPPO3PumpAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmWarning.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmWarning.TimerTime = 5.000000e+00
Attr Super.FrequencyConverter.AlarmWarning.LockAttribute = 1
Attr Super.FrequencyConverter.AlarmError.DetectOn = 1
Attr Super.FrequencyConverter.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -166990,6 +167013,7 @@ Fc PPO3 Motor Aggregate
Attr Super.FrequencyConverter.AlarmConnection.MoreText = ""
Attr Super.FrequencyConverter.AlarmConnection.Attribute = "BaseComponent:Class-BaseFcPPO3PumpAggr-Template.Super.FrequencyConverter"
Attr Super.FrequencyConverter.AlarmConnection.CtrlPosition = 1
Attr Super.FrequencyConverter.AlarmConnection.TimerTime = 3.000000e+00
Attr Super.FrequencyConverter.AlarmConnection.LockAttribute = 1
Attr Super.FrequencyConverter.DefTrend = "BaseComponent:Class-BaseFcPPO3PumpAggr-Template.Super.FrequencyConverter.PlotGroup"
Attr Super.FrequencyConverter.TrendActSpeed.Multiple = 1
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
View file @
e01bb94c
...
...
@@ -334,7 +334,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Danfoss_Converter_FC300_PPO3 2158198784 01-JAN-1970 01:00:00.00
Body RtBody
18-MAR-2008 17:06:08.88
Body RtBody
27-JAN-2014 10:47:32.95
Attr Super.Specification = "Danfoss Frequency converter FC300 with Profibus PPO3 protocol"
Attr Super.StatusWordSW.Description = "Status Word, from converter"
Attr Super.StatusWordSW.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO3IoModule.I_SW"
...
...
@@ -357,6 +357,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.AlarmLocalMod.MoreText = ""
Attr Super.AlarmLocalMod.Attribute = "OtherManufacturer:Class-Danfoss_Converter_FC300_PPO3-Template"
Attr Super.AlarmLocalMod.CtrlPosition = 1
Attr Super.AlarmLocalMod.TimerTime = 3.000000e+00
Attr Super.AlarmLocalMod.LockAttribute = 1
Attr Super.AlarmTripped.DetectOn = 1
Attr Super.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -375,6 +376,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.AlarmWarning.MoreText = ""
Attr Super.AlarmWarning.Attribute = "OtherManufacturer:Class-Danfoss_Converter_FC300_PPO3-Template"
Attr Super.AlarmWarning.CtrlPosition = 1
Attr Super.AlarmWarning.TimerTime = 5.000000e+00
Attr Super.AlarmWarning.LockAttribute = 1
Attr Super.AlarmError.DetectOn = 1
Attr Super.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -386,6 +388,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.AlarmError.CtrlPosition = 1
Attr Super.AlarmError.LockAttribute = 1
Attr Super.AlarmConnection.MoreText = ""
Attr Super.AlarmConnection.TimerTime = 3.000000e+00
Attr Super.DefTrend = "OtherManufacturer:Class-Danfoss_Converter_FC300_PPO3-Template.Super.PlotGroup"
Attr Super.DataSheet = "$pwr_lang/dsh/danfoss_converter_fc300.pdf"
Attr Super.TrendActSpeed.Multiple = 1
...
...
@@ -439,7 +442,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Danfoss_Converter_FC300_PPO5 2157936640 01-JAN-1970 01:00:00.00
Body RtBody
18-MAR-2008 17:04:31.24
Body RtBody
27-JAN-2014 10:48:02.60
Attr Super.Specification = "Frequency converter Danfoss FC300 with Profibus PPO5 protocol"
Attr Super.InIdPar.Description = "Parameter Identification, from converter"
Attr Super.InIdPar.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO5IoModule.I_ID"
...
...
@@ -503,6 +506,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.AlarmLocalMod.MoreText = ""
Attr Super.AlarmLocalMod.Attribute = "OtherManufacturer:Class-Danfoss_Converter_FC300_PPO5-Template"
Attr Super.AlarmLocalMod.CtrlPosition = 1
Attr Super.AlarmLocalMod.TimerTime = 3.000000e+00
Attr Super.AlarmLocalMod.LockAttribute = 1
Attr Super.AlarmTripped.DetectOn = 1
Attr Super.AlarmTripped.DetectText = "Frequency converter tripped, reset is required"
...
...
@@ -521,6 +525,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.AlarmWarning.MoreText = ""
Attr Super.AlarmWarning.Attribute = "OtherManufacturer:Class-Danfoss_Converter_FC300_PPO5-Template"
Attr Super.AlarmWarning.CtrlPosition = 1
Attr Super.AlarmWarning.TimerTime = 5.000000e+00
Attr Super.AlarmWarning.LockAttribute = 1
Attr Super.AlarmError.DetectOn = 1
Attr Super.AlarmError.DetectText = "Frequency converter error"
...
...
@@ -532,6 +537,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.AlarmError.CtrlPosition = 1
Attr Super.AlarmError.LockAttribute = 1
Attr Super.AlarmConnection.MoreText = ""
Attr Super.AlarmConnection.TimerTime = 3.000000e+00
Attr Super.DefTrend = "OtherManufacturer:Class-Danfoss_Converter_FC300_PPO5-Template.Super.PlotGroup"
Attr Super.DataSheet = "$pwr_lang/dsh/danfoss_converter_fc300.pdf"
Attr Super.TrendActSpeed.Multiple = 1
Write
Preview
Markdown
is supported
0%
Try again
or
attach a new file
Attach a file
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Cancel
Please
register
or
sign in
to comment