Shiju Jose authored
Presently the error handling code sets the reset level required for the recovery of the hw errors to the reset framework in the error_detected AER callback. However the rest_event would be called later from the slot_reset callback. This can cause issue of using the wrong reset_level if a high priority reset request occur before the slot_reset is called. This patch delays setting of the reset level, required for the hw errors, to the reset framework until the slot_reset is called. Reported-by: Salil Mehta <salil.mehta@huawei.com> Signed-off-by: Shiju Jose <shiju.jose@huawei.com> Signed-off-by: Weihang Li <liweihang@hisilicon.com> Signed-off-by: Peng Li <lipeng321@huawei.com> Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
123297b7