In order to do a clause 22 access to the PHY registers of the ADIN1110, we have to write the MDIO frame to the ADIN1110_MDIOACC register, and then poll the MDIO_TRDONE bit (for a 1) in the same register. The device will set this bit to 1 once the internal MDIO transaction is done. In practice, this bit takes ~50 - 60 us to be set. The first attempt to poll the bit is right after the ADIN1110_MDIOACC register is written, so it will always be read as 0. The next check will only be done after 10 ms, which will result in the MDIO transactions taking a long time to complete. Reduce this polling interval to 100 us. Since this interval is short enough, switch the poll function to readx_poll_timeout_atomic() instead. Reviewed-by: Nuno Sa <nuno.sa@analog.com> Signed-off-by: Ciprian Regus <ciprian.regus@analog.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Link: https://lore.kernel.org/r/20240223162129.154114-1-ciprian.regus@analog.comSigned-off-by: Paolo Abeni <pabeni@redhat.com>