Jonathan McDowell authored
The move to a combined driver for the QCOM SCM hardware changed the io_writel and io_readl helpers to use non-atomic calls, despite the commit message saying that atomic was a better option. This breaks these helpers on hardware that uses the old legacy convention (access fails with a -95 return code). Switch back to using the atomic calls. Observed as a failure routing GPIO interrupts to the Apps processor on an IPQ8064; fix is confirmed as correctly allowing the interrupts to be routed and observed. Reviewed-by: Elliot Berman <eberman@codeaurora.org> Fixes: 57d3b816 ("firmware: qcom_scm: Remove thin wrappers") Cc: stable@vger.kernel.org Signed-off-by: Jonathan McDowell <noodles@earth.li> Link: https://lore.kernel.org/r/20200704172334.GA759@earth.liSigned-off-by: Bjorn Andersson <bjorn.andersson@linaro.org>
b88c2828