Niklas Söderlund authored
Instead of using hard coded clock increment values for each SoC derive the clock increment from the module clock. This is done in preparation to support a second platform, R-Car V4H that uses a 200Mhz clock compared with the 320Mhz clock used on R-Car S4. Tested on both SoCs, S4 reports a clock of 320000000Hz which gives a value of 0x19000000. Documentation says a 320Mhz clock is used and the correct increment for that clock is 0x19000000. V4H reports a clock of 199999992Hz which gives a value of 0x2800001a. Documentation says a 200Mhz clock is used and the correct increment for that clock is 0x28000000. Suggested-by: Geert Uytterhoeven <geert@linux-m68k.org> Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> Reviewed-by: Simon Horman <horms@kernel.org> Signed-off-by: Paolo Abeni <pabeni@redhat.com>
be5f81d3