clocksource/drivers/tegra: Cycles can't be 0
Tegra's timer uses n+1 scheme for the counter, i.e. timer will fire after one tick if 0 is loaded. The minimum and maximum numbers of oneshot ticks are defined by clockevents_config_and_register(min, max) invocation and the min value is set to 1 tick. Hence "cycles" value can't ever be 0, unless it's a bug in clocksource core. Signed-off-by: Dmitry Osipenko <digetx@gmail.com> Acked-by: Jon Hunter <jonathanh@nvidia.com> Acked-by: Thierry Reding <treding@nvidia.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Showing
Please register or sign in to comment