charger-manager: Fix bug related to checking fully charged state of battery
This patch fix bug related to checking fully charged state of battery when charger-manager call is_full_charged() function. After reading property of charger/fuel-gauge through power_supply API, val.intval is more than 1. So, is_full_charged() function always return true. If true, battery means fully charged state. Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com> Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>