Commit 11aade26 authored by Ian Abbott's avatar Ian Abbott Committed by Greg Kroah-Hartman

staging: comedi: cb_pcidas64: update driver comment

Update the comedi driver comment to reflect the fact that manual
attachment of devices is no longer supported.  Also replace the request
to file a bug report about unidentified PCI device IDs with a request to
let the maintainers know about such devices.

Reformat the comment using the usual block comment style.
Signed-off-by: default avatarIan Abbott <abbotti@mev.co.uk>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent dd379fa2
......@@ -36,39 +36,39 @@
************************************************************************/
/*
Driver: cb_pcidas64
Description: MeasurementComputing PCI-DAS64xx, 60XX, and 4020 series with the PLX 9080 PCI controller
Author: Frank Mori Hess <fmhess@users.sourceforge.net>
Status: works
Updated: 2002-10-09
Devices: [Measurement Computing] PCI-DAS6402/16 (cb_pcidas64),
PCI-DAS6402/12, PCI-DAS64/M1/16, PCI-DAS64/M2/16,
PCI-DAS64/M3/16, PCI-DAS6402/16/JR, PCI-DAS64/M1/16/JR,
PCI-DAS64/M2/16/JR, PCI-DAS64/M3/16/JR, PCI-DAS64/M1/14,
PCI-DAS64/M2/14, PCI-DAS64/M3/14, PCI-DAS6013, PCI-DAS6014,
PCI-DAS6023, PCI-DAS6025, PCI-DAS6030,
PCI-DAS6031, PCI-DAS6032, PCI-DAS6033, PCI-DAS6034,
PCI-DAS6035, PCI-DAS6036, PCI-DAS6040, PCI-DAS6052,
PCI-DAS6070, PCI-DAS6071, PCI-DAS4020/12
Configuration options:
[0] - PCI bus of device (optional)
[1] - PCI slot of device (optional)
These boards may be autocalibrated with the comedi_calibrate utility.
To select the bnc trigger input on the 4020 (instead of the dio input),
specify a nonzero channel in the chanspec. If you wish to use an external
master clock on the 4020, you may do so by setting the scan_begin_src
to TRIG_OTHER, and using an INSN_CONFIG_TIMER_1 configuration insn
to configure the divisor to use for the external clock.
Some devices are not identified because the PCI device IDs are not yet
known. If you have such a board, please file a bug report at
https://bugs.comedi.org.
*/
* Driver: cb_pcidas64
* Description: MeasurementComputing PCI-DAS64xx, 60XX, and 4020 series
* with the PLX 9080 PCI controller
* Author: Frank Mori Hess <fmhess@users.sourceforge.net>
* Status: works
* Updated: Fri, 02 Nov 2012 18:58:55 +0000
* Devices: [Measurement Computing] PCI-DAS6402/16 (cb_pcidas64),
* PCI-DAS6402/12, PCI-DAS64/M1/16, PCI-DAS64/M2/16,
* PCI-DAS64/M3/16, PCI-DAS6402/16/JR, PCI-DAS64/M1/16/JR,
* PCI-DAS64/M2/16/JR, PCI-DAS64/M3/16/JR, PCI-DAS64/M1/14,
* PCI-DAS64/M2/14, PCI-DAS64/M3/14, PCI-DAS6013, PCI-DAS6014,
* PCI-DAS6023, PCI-DAS6025, PCI-DAS6030,
* PCI-DAS6031, PCI-DAS6032, PCI-DAS6033, PCI-DAS6034,
* PCI-DAS6035, PCI-DAS6036, PCI-DAS6040, PCI-DAS6052,
* PCI-DAS6070, PCI-DAS6071, PCI-DAS4020/12
*
* Configuration options:
* None.
*
* Manual attachment of PCI cards with the comedi_config utility is not
* supported by this driver; they are attached automatically.
*
* These boards may be autocalibrated with the comedi_calibrate utility.
*
* To select the bnc trigger input on the 4020 (instead of the dio input),
* specify a nonzero channel in the chanspec. If you wish to use an external
* master clock on the 4020, you may do so by setting the scan_begin_src
* to TRIG_OTHER, and using an INSN_CONFIG_TIMER_1 configuration insn
* to configure the divisor to use for the external clock.
*
* Some devices are not identified because the PCI device IDs are not yet
* known. If you have such a board, please let the maintainers know.
*/
/*
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment