Commit 17fe8c8b authored by Akinobu Mita's avatar Akinobu Mita Committed by Sasha Levin

iio: pressure: mpl115: fix temperature offset sign

[ Upstream commit 431386e7 ]

According to the datasheet, the resolusion of temperature sensor is
-5.35 counts/C. Temperature ADC is 472 counts at 25C.
(https://www.sparkfun.com/datasheets/Sensors/Pressure/MPL115A1.pdf
NOTE: This is older revision, but this information is removed from the
latest datasheet from nxp somehow)

Temp [C] = (Tadc - 472) / -5.35 + 25
         = (Tadc - 605.750000) * -0.186915888

So the correct offset is -605.750000.
Signed-off-by: default avatarAkinobu Mita <akinobu.mita@gmail.com>
Acked-by: default avatarPeter Meerwald-Stadler <pmeerw@pmeerw.net>
Cc: <Stable@vger.kernel.org>
Signed-off-by: default avatarJonathan Cameron <jic23@kernel.org>
Signed-off-by: default avatarSasha Levin <sasha.levin@oracle.com>
parent 5b20b25a
...@@ -117,7 +117,7 @@ static int mpl115_read_raw(struct iio_dev *indio_dev, ...@@ -117,7 +117,7 @@ static int mpl115_read_raw(struct iio_dev *indio_dev,
*val = ret >> 6; *val = ret >> 6;
return IIO_VAL_INT; return IIO_VAL_INT;
case IIO_CHAN_INFO_OFFSET: case IIO_CHAN_INFO_OFFSET:
*val = 605; *val = -605;
*val2 = 750000; *val2 = 750000;
return IIO_VAL_INT_PLUS_MICRO; return IIO_VAL_INT_PLUS_MICRO;
case IIO_CHAN_INFO_SCALE: case IIO_CHAN_INFO_SCALE:
......
Markdown is supported