Commit 2a5f4183 authored by Linus Walleij's avatar Linus Walleij Committed by Sebastian Reichel

power: supply: ab8500: Standardize voltages

The nominal voltage in this charge driver corresponds to
both the voltage_min_design_uv and voltage_max_design_uv
of struct power_supply_battery_info so assign both if this
is undefined.

The overcharge max voltage (when the charger should cut off)
is migrated at the same time so we move both voltages to
struct power_supply_battery_info.

Adjust the code to deal directly with the microvolt values
instead of converting them to millivolts.

Add *_uv suffixes for clarity and to make sure we have
changed all code sites using this member.
Signed-off-by: default avatarLinus Walleij <linus.walleij@linaro.org>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 2d3559a5
......@@ -374,8 +374,6 @@ struct ab8500_maxim_parameters {
* struct ab8500_battery_type - different batteries supported
* @resis_high: battery upper resistance limit
* @resis_low: battery lower resistance limit
* @nominal_voltage: Nominal voltage of the battery in mV
* @termination_vol: max voltage upto which battery can be charged
* @termination_curr battery charging termination current in mA
* @recharge_cap battery capacity limit that will trigger a new
* full charging cycle in the case where maintenan-
......@@ -401,8 +399,6 @@ struct ab8500_maxim_parameters {
struct ab8500_battery_type {
int resis_high;
int resis_low;
int nominal_voltage;
int termination_vol;
int termination_curr;
int recharge_cap;
int normal_cur_lvl;
......
......@@ -84,8 +84,6 @@ static struct ab8500_battery_type bat_type_thermistor_unknown = {
.resis_high = 0,
.resis_low = 0,
.battery_resistance = 300,
.nominal_voltage = 3700,
.termination_vol = 4050,
.termination_curr = 200,
.recharge_cap = 95,
.normal_cur_lvl = 400,
......@@ -191,6 +189,21 @@ int ab8500_bm_of_probe(struct power_supply *psy,
if (bi->charge_full_design_uah < 0)
/* The default capacity is 612 mAh for unknown batteries */
bi->charge_full_design_uah = 612000;
/*
* All of these voltages need to be specified or we will simply
* fall back to safe defaults.
*/
if ((bi->voltage_min_design_uv < 0) ||
(bi->voltage_max_design_uv < 0) ||
(bi->overvoltage_limit_uv < 0)) {
/* Nominal voltage is 3.7V for unknown batteries */
bi->voltage_min_design_uv = 3700000;
bi->voltage_max_design_uv = 3700000;
/* Termination voltage (overcharge limit) 4.05V */
bi->overvoltage_limit_uv = 4050000;
}
if (bi->temp_min == INT_MIN)
bi->temp_min = AB8500_TEMP_UNDER;
if (bi->temp_max == INT_MAX)
......
......@@ -86,7 +86,7 @@ struct ab8500_chargalg_current_step_status {
struct ab8500_chargalg_battery_data {
int temp;
int volt;
int volt_uv;
int avg_curr;
int inst_curr;
int percent;
......@@ -792,8 +792,8 @@ static void ab8500_chargalg_end_of_charge(struct ab8500_chargalg *di)
{
if (di->charge_status == POWER_SUPPLY_STATUS_CHARGING &&
di->charge_state == STATE_NORMAL &&
!di->maintenance_chg && (di->batt_data.volt >=
di->bm->bat_type->termination_vol ||
!di->maintenance_chg && (di->batt_data.volt_uv >=
di->bm->bi.overvoltage_limit_uv ||
di->events.usb_cv_active || di->events.ac_cv_active) &&
di->batt_data.avg_curr <
di->bm->bat_type->termination_curr &&
......@@ -1160,7 +1160,7 @@ static int ab8500_chargalg_get_ext_psy_data(struct device *dev, void *data)
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
switch (ext->desc->type) {
case POWER_SUPPLY_TYPE_BATTERY:
di->batt_data.volt = ret.intval / 1000;
di->batt_data.volt_uv = ret.intval;
break;
case POWER_SUPPLY_TYPE_MAINS:
di->chg_info.ac_volt = ret.intval / 1000;
......@@ -1397,7 +1397,7 @@ static void ab8500_chargalg_algorithm(struct ab8500_chargalg *di)
"State %s Active_chg %d Chg_status %d AC %d USB %d "
"AC_online %d USB_online %d AC_CV %d USB_CV %d AC_I %d "
"USB_I %d AC_Vset %d AC_Iset %d USB_Vset %d USB_Iset %d\n",
di->batt_data.volt,
di->batt_data.volt_uv,
di->batt_data.avg_curr,
di->batt_data.inst_curr,
di->batt_data.temp,
......
......@@ -157,7 +157,7 @@ struct inst_curr_result_list {
* @node: a list of AB8500 FGs, hence prepared for reentrance
* @irq holds the CCEOC interrupt number
* @vbat: Battery voltage in mV
* @vbat_nom: Nominal battery voltage in mV
* @vbat_nom_uv: Nominal battery voltage in uV
* @inst_curr: Instantenous battery current in mA
* @avg_curr: Average battery current in mA
* @bat_temp battery temperature
......@@ -199,7 +199,7 @@ struct ab8500_fg {
struct list_head node;
int irq;
int vbat;
int vbat_nom;
int vbat_nom_uv;
int inst_curr;
int avg_curr;
int bat_temp;
......@@ -1013,11 +1013,16 @@ static int ab8500_fg_convert_mah_to_uwh(struct ab8500_fg *di, int cap_mah)
u64 div_res;
u32 div_rem;
div_res = ((u64) cap_mah) * ((u64) di->vbat_nom);
div_rem = do_div(div_res, 1000);
/*
* Capacity is in milli ampere hours (10^-3)Ah
* Nominal voltage is in microvolts (10^-6)V
* divide by 1000000 after multiplication to get to mWh
*/
div_res = ((u64) cap_mah) * ((u64) di->vbat_nom_uv);
div_rem = do_div(div_res, 1000000);
/* Make sure to round upwards if necessary */
if (div_rem >= 1000 / 2)
if (div_rem >= 1000000 / 2)
div_res++;
return (int) div_res;
......@@ -2247,7 +2252,8 @@ static int ab8500_fg_get_ext_psy_data(struct device *dev, void *data)
di->bat_cap.max_mah =
di->bat_cap.max_mah_design;
di->vbat_nom = b->nominal_voltage;
di->vbat_nom_uv =
di->bm->bi.voltage_max_design_uv;
}
if (ret.intval)
......@@ -3078,8 +3084,7 @@ static int ab8500_fg_probe(struct platform_device *pdev)
di->bat_cap.max_mah_design = di->bm->bi.charge_full_design_uah;
di->bat_cap.max_mah = di->bat_cap.max_mah_design;
di->vbat_nom = di->bm->bat_type->nominal_voltage;
di->vbat_nom_uv = di->bm->bi.voltage_max_design_uv;
di->init_capacity = true;
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment