net: enetc: fix the incorrect clearing of IF_MODE bits
The enetc phylink .mac_config handler intends to clear the IFMODE field (bits 1:0) of the PM0_IF_MODE register, but incorrectly clears all the other fields instead. For normal operation, the bug was inconsequential, due to the fact that we write the PM0_IF_MODE register in two stages, first in phylink .mac_config (which incorrectly cleared out a bunch of stuff), then we update the speed and duplex to the correct values in phylink .mac_link_up. Judging by the code (not tested), it looks like maybe loopback mode was broken, since this is one of the settings in PM0_IF_MODE which is incorrectly cleared. Fixes: c76a9721 ("net: enetc: force the RGMII speed and duplex instead of operating in inband mode") Reported-by: Pavel Machek (CIP) <pavel@denx.de> Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Signed-off-by: David S. Miller <davem@davemloft.net>