drm/msm/dpu: Fix error recovery after failing to enable clocks
If enabling clocks fails in msm_dss_enable_clk() the code to unwind the settings starts at 'i' which is the clock that just failed. While this isn't harmful it does result in a number of warnings from the clock subsystem while trying to unpreare/disable the very clock that had just failed to prepare/enable. Skip the current failed clock during the unwind to to avoid the extra log spew. Signed-off-by: Jordan Crouse <jcrouse@codeaurora.org> Signed-off-by: Rob Clark <robdclark@chromium.org>