Commit 43e7ef64 authored by Linus Torvalds's avatar Linus Torvalds

Merge tag 'hwmon-for-v6.8-rc3' of...

Merge tag 'hwmon-for-v6.8-rc3' of git://git.kernel.org/pub/scm/linux/kernel/git/groeck/linux-staging

Pull hwmon fixes from Guenter Roeck:

 - pmbus/mp2975: Fix driver initialization

 - gigabyte_waterforce: Add missing unlock in error handling path

* tag 'hwmon-for-v6.8-rc3' of git://git.kernel.org/pub/scm/linux/kernel/git/groeck/linux-staging:
  hwmon: (pmbus/mp2975) Correct comment inside 'mp2975_read_byte_data'
  hwmon: (pmbus/mp2975) Fix driver initialization for MP2975 device
  hwmon: gigabyte_waterforce: Fix locking bug in waterforce_get_status()
parents 79837a7c 91564418
......@@ -146,7 +146,7 @@ static int waterforce_get_status(struct waterforce_data *priv)
/* Send command for getting status */
ret = waterforce_write_expanded(priv, get_status_cmd, GET_STATUS_CMD_LENGTH);
if (ret < 0)
return ret;
goto unlock_and_return;
ret = wait_for_completion_interruptible_timeout(&priv->status_report_received,
msecs_to_jiffies(STATUS_VALIDITY));
......
......@@ -126,6 +126,21 @@ static const struct regulator_desc __maybe_unused mp2975_reg_desc[] = {
#define to_mp2975_data(x) container_of(x, struct mp2975_data, info)
static int mp2975_read_byte_data(struct i2c_client *client, int page, int reg)
{
switch (reg) {
case PMBUS_VOUT_MODE:
/*
* Report direct format as configured by MFR_DC_LOOP_CTRL.
* Unlike on MP2971/MP2973 the reported VOUT_MODE isn't automatically
* internally updated, but always reads as PB_VOUT_MODE_VID.
*/
return PB_VOUT_MODE_DIRECT;
default:
return -ENODATA;
}
}
static int
mp2975_read_word_helper(struct i2c_client *client, int page, int phase, u8 reg,
u16 mask)
......@@ -869,6 +884,7 @@ static struct pmbus_driver_info mp2975_info = {
PMBUS_HAVE_IIN | PMBUS_HAVE_IOUT | PMBUS_HAVE_STATUS_IOUT |
PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP | PMBUS_HAVE_POUT |
PMBUS_HAVE_PIN | PMBUS_HAVE_STATUS_INPUT | PMBUS_PHASE_VIRTUAL,
.read_byte_data = mp2975_read_byte_data,
.read_word_data = mp2975_read_word_data,
#if IS_ENABLED(CONFIG_SENSORS_MP2975_REGULATOR)
.num_regulators = 1,
......
Markdown is supported