drm/amd/display: Check clock table return
During the load processes for Renoir, our display code needs to retrieve the SMU clock and voltage table, however, this operation can fail which means that we have to check this scenario. Currently, we are not handling this case properly and as a result, we have seen the following dmesg log during the boot: RIP: 0010:rn_clk_mgr_construct+0x129/0x3d0 [amdgpu] ... Call Trace: dc_clk_mgr_create+0x16a/0x1b0 [amdgpu] dc_create+0x231/0x760 [amdgpu] This commit fixes this issue by checking the return status retrieved from the clock table before try to populate any bandwidth. Signed-off-by: Rodrigo Siqueira <Rodrigo.Siqueira@amd.com> Acked-by: Aurabindo Pillai <aurabindo.pillai@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>