igc: Fix PPS delta between two synchronized end-points
This patch fix the pulse per second output delta between two synchronized end-points. Based on Intel Discrete I225 Software User Manual Section 4.2.15 TimeSync Auxiliary Control Register, ST0[Bit 4] and ST1[Bit 7] must be set to ensure that clock output will be toggles based on frequency value defined. This is to ensure that output of the PPS is aligned with the clock. How to test: 1) Running time synchronization on both end points. Ex: ptp4l --step_threshold=1 -m -f gPTP.cfg -i <interface name> 2) Configure PPS output using below command for both end-points Ex: SDP0 on I225 REV4 SKU variant ./testptp -d /dev/ptp0 -L 0,2 ./testptp -d /dev/ptp0 -p 1000000000 3) Measure the output using analyzer for both end-points Fixes: 87938851 ("igc: enable auxiliary PHC functions for the i225") Signed-off-by: Christopher S Hall <christopher.s.hall@intel.com> Signed-off-by: Muhammad Husaini Zulkifli <muhammad.husaini.zulkifli@intel.com> Acked-by: Sasha Neftin <sasha.neftin@intel.com> Tested-by: Naama Meir <naamax.meir@linux.intel.com> Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>