Commit 6f9b4100 authored by Andreas Herrmann's avatar Andreas Herrmann Committed by Ingo Molnar

x86, apic: Clear APIC Timer Initial Count Register on shutdown

Commit a98f8fd2 (x86: apic reset
counter on shutdown) set the counter to max to avoid spurious
interrupts when the timer is re-enabled.

(In theory) you'll still get a spurious interrupt if spending
more than 344 seconds with this interrupt disabled and then
unmasking it.

The right thing to do is to clear the register. This disables
the interrupt from happening (at least it does on AMD hardware).
Signed-off-by: default avatarAndreas Herrmann <andreas.herrmann3@amd.com>
LKML-Reference: <20091027100138.GB30802@alberich.amd.com>
Signed-off-by: default avatarIngo Molnar <mingo@elte.hu>
parent f88f2b4f
...@@ -444,7 +444,7 @@ static void lapic_timer_setup(enum clock_event_mode mode, ...@@ -444,7 +444,7 @@ static void lapic_timer_setup(enum clock_event_mode mode,
v = apic_read(APIC_LVTT); v = apic_read(APIC_LVTT);
v |= (APIC_LVT_MASKED | LOCAL_TIMER_VECTOR); v |= (APIC_LVT_MASKED | LOCAL_TIMER_VECTOR);
apic_write(APIC_LVTT, v); apic_write(APIC_LVTT, v);
apic_write(APIC_TMICT, 0xffffffff); apic_write(APIC_TMICT, 0);
break; break;
case CLOCK_EVT_MODE_RESUME: case CLOCK_EVT_MODE_RESUME:
/* Nothing to do here */ /* Nothing to do here */
......