Commit 7cc8524f authored by Jason Gerecke's avatar Jason Gerecke Committed by Jiri Kosina

HID: wacom: Skip processing of touches with negative slot values

The `input_mt_get_slot_by_key` function may return a negative value
if an error occurs (e.g. running out of slots). If this occurs we
should really avoid reporting any data for the slot.
Signed-off-by: default avatarPing Cheng <ping.cheng@wacom.com>
Signed-off-by: default avatarJason Gerecke <jason.gerecke@wacom.com>
Signed-off-by: default avatarJiri Kosina <jkosina@suse.cz>
parent 6ca2350e
...@@ -2548,6 +2548,9 @@ static void wacom_wac_finger_slot(struct wacom_wac *wacom_wac, ...@@ -2548,6 +2548,9 @@ static void wacom_wac_finger_slot(struct wacom_wac *wacom_wac,
int slot; int slot;
slot = input_mt_get_slot_by_key(input, hid_data->id); slot = input_mt_get_slot_by_key(input, hid_data->id);
if (slot < 0)
return;
input_mt_slot(input, slot); input_mt_slot(input, slot);
input_mt_report_slot_state(input, MT_TOOL_FINGER, prox); input_mt_report_slot_state(input, MT_TOOL_FINGER, prox);
} }
......