Commit 7ecc7701 authored by Ricardo Ribalda Delgado's avatar Ricardo Ribalda Delgado Committed by Greg Kroah-Hartman

serial: 8250_fintek: Return -EINVAL on invalid configuration

Hardware does not support having the same RTS level during RX and TX
when RS485 mode is on (URA in Fintek terminology).

The manufacturer has also confirmed that the delays are not enabled if
the RS485 mode is not enabled.

Therefore we should return -EINVAL if the user wants to have the same
value for RTS_ON_SEND and RTS_AFTER_SEND.

Cc: "Ji-Ze Hong (Peter Hong)" <hpeter@gmail.com>
Cc: Lukas Wunner <lukas@wunner.de>
Signed-off-by: default avatarRicardo Ribalda Delgado <ricardo.ribalda@gmail.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent e5656d43
......@@ -197,10 +197,17 @@ static int fintek_8250_rs485_config(struct uart_port *port,
if (!pdata)
return -EINVAL;
if (rs485->flags & SER_RS485_ENABLED)
/* Hardware do not support same RTS level on send and receive */
if (!(rs485->flags & SER_RS485_RTS_ON_SEND) ==
!(rs485->flags & SER_RS485_RTS_AFTER_SEND))
return -EINVAL;
if (rs485->flags & SER_RS485_ENABLED) {
memset(rs485->padding, 0, sizeof(rs485->padding));
else
config |= RS485_URA;
} else {
memset(rs485, 0, sizeof(*rs485));
}
rs485->flags &= SER_RS485_ENABLED | SER_RS485_RTS_ON_SEND |
SER_RS485_RTS_AFTER_SEND;
......@@ -215,12 +222,6 @@ static int fintek_8250_rs485_config(struct uart_port *port,
config |= RXW4C_IRA;
}
if ((!!(rs485->flags & SER_RS485_RTS_ON_SEND)) ==
(!!(rs485->flags & SER_RS485_RTS_AFTER_SEND)))
rs485->flags &= ~SER_RS485_ENABLED;
else
config |= RS485_URA;
if (rs485->flags & SER_RS485_RTS_ON_SEND)
config |= RTS_INVERT;
......
Markdown is supported