s390/con3270: fix use of uninitialised data
commit c14f2aac upstream. con3270 contains an optimisation that reduces the amount of data to be transmitted to the 3270 terminal by putting a Repeat to Address (RA) order into the data stream. The RA order itself takes up space, so con3270 only uses it if there's enough space left in the line buffer. Otherwise it just pads out the line manually. For lines too long to include the RA order, one byte was left uninitialised. This was caused by an off-by-one bug in the loop that pads out the line. Since the buffer is allocated from a common pool, the single byte left uninitialised contained some previous buffer content. Usually this was just a space or some character (which can result in clutter but is otherwise harmless). Sometimes, however, it was a Repeat to Address order, messing up the entire screen layout and causing the display to send the entire buffer content on every keystroke. Fixes: f51320a5 ("[PATCH] s390: new 3270 driver.") (tglx/history.git) Reported-by: Liu Jing <liujbjl@linux.vnet.ibm.com> Tested-by: Jing Liu <liujbjl@linux.vnet.ibm.com> Tested-by: Yang Chen <bjcyang@linux.vnet.ibm.com> Signed-off-by: Sascha Silbe <silbe@linux.vnet.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Showing
Please register or sign in to comment