net/mlx5: E-Switch, Re-enable RoCE on mode change only after FDB destroy
[ Upstream commit 5bae8c03 ] We must re-enable RoCE on the e-switch management port (PF) only after destroying the FDB in its switchdev/offloaded mode. Otherwise, when encapsulation is supported, this re-enablement will fail. Also, it's more natural and symmetric to disable RoCE on the PF before we create the FDB under switchdev mode, so do that as well and revert if getting into error during the mode change later. Fixes: 9da34cd3 ('net/mlx5: Disable RoCE on the e-switch management [..]') Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Reviewed-by: Hadar Hen Zion <hadarh@mellanox.com> Signed-off-by: Saeed Mahameed <saeedm@mellanox.com> Signed-off-by: Sasha Levin <alexander.levin@verizon.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>