Commit a6e2846c authored by Sudarsana Reddy Kalluru's avatar Sudarsana Reddy Kalluru Committed by David S. Miller

bnx2x: Use the correct divisor value for PHC clock readings.

Time Sync (PTP) implementation uses the divisor/shift value for converting
the clock ticks to nanoseconds. Driver currently defines shift value as 1,
this results in the nanoseconds value to be calculated as half the actual
value. Hence the user application fails to synchronize the device clock
value with the PTP master device clock. Need to use the 'shift' value of 0.
Signed-off-by: default avatarSony.Chacko <Sony.Chacko@cavium.com>
Signed-off-by: default avatarSudarsana Reddy Kalluru <Sudarsana.Kalluru@cavium.com>
Signed-off-by: default avatarYuval Mintz <Yuval.Mintz@cavium.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent f18a37ff
...@@ -15241,7 +15241,7 @@ static void bnx2x_init_cyclecounter(struct bnx2x *bp) ...@@ -15241,7 +15241,7 @@ static void bnx2x_init_cyclecounter(struct bnx2x *bp)
memset(&bp->cyclecounter, 0, sizeof(bp->cyclecounter)); memset(&bp->cyclecounter, 0, sizeof(bp->cyclecounter));
bp->cyclecounter.read = bnx2x_cyclecounter_read; bp->cyclecounter.read = bnx2x_cyclecounter_read;
bp->cyclecounter.mask = CYCLECOUNTER_MASK(64); bp->cyclecounter.mask = CYCLECOUNTER_MASK(64);
bp->cyclecounter.shift = 1; bp->cyclecounter.shift = 0;
bp->cyclecounter.mult = 1; bp->cyclecounter.mult = 1;
} }
......