serial: imx: set receiver level before starting uart
Set the receiver level to something > 0 before calling imx_uart_start_rx in rs485_config. This is necessary to avoid an interrupt storm that might prevent the system from booting. This was seen on an i.MX7 device when the rs485-rts-active-low property was active in the device tree. Fixes: 6d215f83 ("serial: imx: warn user when using unsupported configuration") Cc: stable <stable@kernel.org> Signed-off-by: Stefan Eichenberger <stefan.eichenberger@toradex.com> Link: https://lore.kernel.org/r/20240621153829.183780-1-eichest@gmail.comSigned-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>