ARM/netx/time: Migrate to new 'set-state' interface
Migrate netx driver to the new 'set-state' interface provided by
clockevents core, the earlier 'set-mode' interface is marked obsolete
now.
This also enables us to implement callbacks for new states of clockevent
devices, for example: ONESHOT_STOPPED.
We aren't writing zero twice on the control register for shutdown or
resume state now.
Cc: Russell King <linux@arm.linux.org.uk>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>