spi: orion: fix incorrect handling of cell-index DT property
commit e06871cd upstream. In commit f814f9ac ("spi/orion: add device tree binding"), Device Tree support was added to the spi-orion driver. However, this commit reads the "cell-index" property, without taking into account the fact that DT properties are big-endian encoded. Since most of the platforms using spi-orion with DT have apparently not used anything but cell-index = <0>, the problem was not visible. But as soon as one starts using cell-index = <1>, the problem becomes clearly visible, as the master->bus_num gets a wrong value (actually it gets the value 0, which conflicts with the first bus that has cell-index = <0>). This commit fixes that by using of_property_read_u32() to read the property value, which does the appropriate endianness conversion when needed. Fixes: f814f9ac ("spi/orion: add device tree binding") Signed-off-by: Thomas Petazzoni <thomas.petazzoni@free-electrons.com> Acked-by: Sebastian Hesselbarth <sebastian.hesselbarth@gmail.com> Signed-off-by: Mark Brown <broonie@linaro.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Showing
Please register or sign in to comment