USB: RTS/DTR signal patch for airprime driver
I encountered some problems with the airprime driver in use with a Novatel Merlin XU870: Closing an open Connection to e.g. /dev/ttyUSB0 doesn't reset the RTS/DTR lines of the Modem. Consequently, when I use minicom to establish a connection by "ATD*99#" the modem doesn't hang up even if i exit minicom and so I cannot reuse the modem unless I remove it and plug it in again. With the attached patch, the RTS/DTR lines are resetted on a close. The code was mainly taken from the option.c driver.