md: fix for divide error in status_resync
BugLink: https://bugs.launchpad.net/bugs/1838467 [ Upstream commit 9642fa73 ] Stopping external metadata arrays during resync/recovery causes retries, loop of interrupting and starting reconstruction, until it hit at good moment to stop completely. While these retries curr_mark_cnt can be small- especially on HDD drives, so subtraction result can be smaller than 0. However it is casted to uint without checking. As a result of it the status bar in /proc/mdstat while stopping is strange (it jumps between 0% and 99%). The real problem occurs here after commit 72deb455 ("block: remove CONFIG_LBDAF"). Sector_div() macro has been changed, now the divisor is casted to uint32. For db = -8 the divisior(db/32-1) becomes 0. Check if db value can be really counted and replace these macro by div64_u64() inline. Signed-off-by: Mariusz Tkaczyk <mariusz.tkaczyk@intel.com> Signed-off-by: Song Liu <songliubraving@fb.com> Signed-off-by: Sasha Levin <sashal@kernel.org> Signed-off-by: Connor Kuehl <connor.kuehl@canonical.com> Signed-off-by: Khalid Elmously <khalid.elmously@canonical.com>
Showing
Please register or sign in to comment