Commit e853c93b authored by Vladimir Kondratiev's avatar Vladimir Kondratiev Committed by Kalle Valo

wil6210: stop_ap to leave interface closed

cfg80211_ops.stop_ap supposed to have interface carried turned off as
post condition. Fulfill this requirement.
Signed-off-by: default avatarVladimir Kondratiev <qca_vkondrat@qca.qualcomm.com>
Signed-off-by: default avatarKalle Valo <kvalo@qca.qualcomm.com>
parent de9084ef
......@@ -822,13 +822,9 @@ static int wil_cfg80211_stop_ap(struct wiphy *wiphy,
wmi_pcp_stop(wil);
__wil_down(wil);
__wil_up(wil);
mutex_unlock(&wil->mutex);
/* some functions above might fail (e.g. __wil_up). Nevertheless, we
* return success because AP has stopped
*/
return 0;
}
......