Commit e9feeb20 authored by Ralf Baechle's avatar Ralf Baechle

[MIPS] IP22: Fix serial console detection

    
From: Kaj-Michael Lang <milang@tal.org>
    
In ip22-setup.c the checks for serial/graphics console logic does
not check if ARCS console=g but the machine is using serial console, as
it does if no keyboard is attached.
    
This patch adds a check if ConsoleOut is serial. There might also be
support for other graphics than Newport soon...
Signed-off-by: default avatarRalf Baechle <ralf@linux-mips.org>
parent c5033d78
......@@ -56,6 +56,7 @@ extern void ip22_time_init(void) __init;
void __init plat_setup(void)
{
char *ctype;
char *cserial;
board_be_init = ip22_be_init;
ip22_time_init();
......@@ -81,9 +82,14 @@ void __init plat_setup(void)
/* ARCS console environment variable is set to "g?" for
* graphics console, it is set to "d" for the first serial
* line and "d2" for the second serial line.
*
* Need to check if the case is 'g' but no keyboard:
* (ConsoleIn/Out = serial)
*/
ctype = ArcGetEnvironmentVariable("console");
if (ctype && *ctype == 'd') {
cserial = ArcGetEnvironmentVariable("ConsoleOut");
if ((ctype && *ctype == 'd') || (cserial && *cserial == 's')) {
static char options[8];
char *baud = ArcGetEnvironmentVariable("dbaud");
if (baud)
......@@ -91,7 +97,7 @@ void __init plat_setup(void)
add_preferred_console("ttyS", *(ctype + 1) == '2' ? 1 : 0,
baud ? options : NULL);
} else if (!ctype || *ctype != 'g') {
/* Use ARC if we don't want serial ('d') or Newport ('g'). */
/* Use ARC if we don't want serial ('d') or graphics ('g'). */
prom_flags |= PROM_FLAG_USE_AS_CONSOLE;
add_preferred_console("arc", 0, NULL);
}
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment