ARM: dts: dra7: Fix timer nodes properly for timer_sys_ck clocks
The commit 5390130f ("ARM: dts: dra7: add timer_sys_ck entries for IPU/DSP timers") was added to allow the OMAP clocksource timer driver to use the clock aliases when reconfiguring the parent clock source for the timer functional clocks after the timer_sys_ck clock aliases got cleaned up in commit a8202cd5 ("clk: ti: dra7: drop unnecessary clock aliases"). The above patch however has missed adding the entries for couple of timers (14, 15 and 16), and also added erroneously in the parent ti-sysc nodes for couple of clocks (timers 4, 5 and 6). Fix these properly, so that any of these timers can be used with OMAP remoteproc IPU and DSP devices. The always-on timers 1 and 12 are not expected to use this clock source, so they are not modified. Fixes: 5390130f ("ARM: dts: dra7: add timer_sys_ck entries for IPU/DSP timers") Signed-off-by: Suman Anna <s-anna@ti.com> Signed-off-by: Tony Lindgren <tony@atomide.com>