tg3: Abort phy init for 5717 serdes devices
The 5717 serdes devices have a different phy register layout than all other previous serdes devices. This patch aborts the phy init sequence in tg3_phy_reset() if the device is a 5717 serdes. It also aborts the tg3_phy_toggle_apd() operation. Most other operations in the MII_SERDES path are O.K. Signed-off-by: Matt Carlson <mcarlson@broadcom.com> Reviewed-by: Michael Chan <mchan@broadcom.com> Reviewed-by: Benjamin Li <benli@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>