Commit fc75c032 authored by Raju Rangoju's avatar Raju Rangoju Committed by Jakub Kicinski

amd-xgbe: enable PLL_CTL for fixed PHY modes only

PLL control setting(RRC) is needed only in fixed PHY configuration to
fix the peer-peer issues. Without the PLL control setting, the link up
takes longer time in a fixed phy configuration.

Driver implements SW RRC for Autoneg On configuration, hence PLL control
setting (RRC) is not needed for AN On configuration, and can be skipped.

Also, PLL re-initialization is not needed for PHY Power Off and RRC
commands. Otherwise, they lead to mailbox errors. Added the changes
accordingly.

Fixes: daf182d3 ("net: amd-xgbe: Toggle PLL settings during rate change")
Signed-off-by: default avatarRaju Rangoju <Raju.Rangoju@amd.com>
Acked-by: default avatarTom Lendacky <thomas.lendacky@amd.com>
Signed-off-by: default avatarJakub Kicinski <kuba@kernel.org>
parent 1246d086
......@@ -1979,6 +1979,10 @@ static void xgbe_phy_rx_reset(struct xgbe_prv_data *pdata)
static void xgbe_phy_pll_ctrl(struct xgbe_prv_data *pdata, bool enable)
{
/* PLL_CTRL feature needs to be enabled for fixed PHY modes (Non-Autoneg) only */
if (pdata->phy.autoneg != AUTONEG_DISABLE)
return;
XMDIO_WRITE_BITS(pdata, MDIO_MMD_PMAPMD, MDIO_VEND2_PMA_MISC_CTRL0,
XGBE_PMA_PLL_CTRL_MASK,
enable ? XGBE_PMA_PLL_CTRL_ENABLE
......@@ -2029,7 +2033,9 @@ static void xgbe_phy_perform_ratechange(struct xgbe_prv_data *pdata,
xgbe_phy_rx_reset(pdata);
reenable_pll:
/* Enable PLL re-initialization */
/* Enable PLL re-initialization, not needed for PHY Power Off and RRC cmds */
if (cmd != XGBE_MB_CMD_POWER_OFF &&
cmd != XGBE_MB_CMD_RRC)
xgbe_phy_pll_ctrl(pdata, true);
}
......