1. 22 Jul, 2017 1 commit
    • Narcisa Ana Maria Vasile's avatar
      iio: chemical: ccs811: Add support for AMS CCS811 VOC sensor · a94c24a7
      Narcisa Ana Maria Vasile authored
      Add support for CCS811 VOC sensor. This patch adds support
      for reading current and voltage across the sensor and TVOC
      and equivalent CO2 values.
      
      Scale and offset values have been computed according to datasheet:
          - For current: raw value is in microamps
              => 0.001 scale to convert to milliamps
          - For voltage: 1.65V = 1023, therefore 1650mV = 1023
              => 1650.0/1023 = 1.612903 scale to convert to millivolts
          - For eCO2: raw value range is from 400ppm to 8192ppm.
              => (val - 400) * (100 - 0) / (8192 - 400) + 0 =
                 (val - 400) * 0.01283367 => offset: -400, scale = 0.012834
                 to get a percentage value
          -For TVOC: raw value range is from 0ppb to 1187ppb.
              => (val - 0) * 100 / (1187 - 0) + 0 = val * 0.0842459 =>
                  scale = 0.084246 for getting a percentage value
      
      Cc: Daniel Baluta <daniel.baluta@gmail.com>
      Cc: Alison Schofield <amsfield22@gmail.com>
      Signed-off-by: default avatarNarcisa Ana Maria Vasile <narcisaanamaria12@gmail.com>
      Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>