Jacob Keller authored
When shutting down the controlqs, we check if they are initialized before we shut them down and destroy the lock. This is important, as it prevents attempts to access the lock of an already shutdown queue. Unfortunately, we checked rq.head and sq.head as the value to determine if the queue was initialized. This doesn't work, because head is not reset when the queue is shutdown. In some flows, the adminq will have already been shut down prior to calling ice_shutdown_all_ctrlqs. This can result in a crash due to attempting to access the already destroyed mutex. Fix this by using rq.count and sq.count instead. Indeed, ice_shutdown_sq and ice_shutdown_rq already indicate that this is the value we should be using to determine of the queue was initialized. Signed-off-by: Jacob Keller <jacob.e.keller@intel.com> Signed-off-by: Anirudh Venkataramanan <anirudh.venkataramanan@intel.com> Tested-by: Andrew Bowers <andrewx.bowers@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>