Blackfin: fix accidental reset in some boot modes
We read the SWRST (Software Reset) register to get at the last reset state, and then we may configure the DOUBLE_FAULT bit to control behavior when a double fault occurs. But if the lower bits of the register is already set (like UART boot mode on a BF54x), we inadvertently make the system reset by writing to the SYSTEM_RESET field at the same time. So make sure the lower 4 bits are always cleared. Signed-off-by: Sonic Zhang <sonic.zhang@analog.com> Signed-off-by: Mike Frysinger <vapier@gentoo.org>
Showing
Please register or sign in to comment