adt7470: observe the number of temperature sensors to shorten update time
The adt7470 driver currently assumes that 1s is the proper time to wait to read all temperature sensors. However, the correct time is 200ms * number_of_sensors. This patch sets the default time to provide for 10 sensors and then lowers it based on the number of sensor inputs that have nozero values. Signed-off-by: Darrick J. Wong <djwong@us.ibm.com> Cc: Jean Delvare <khali@linux-fr.org> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Showing
Please register or sign in to comment