Commit 30a564be authored by Thomas Gleixner's avatar Thomas Gleixner Committed by H. Peter Anvin

x86, hpet: Restrict read back to affected ATI chipsets

After programming the HPET, we do a readback as a workaround for
ATI/SBx00 chipsets as a synchronization.  Unfortunately this triggers
an erratum in newer ICH chipsets (ICH9+) where reading the comparator
immediately after the write returns the old value.  Furthermore, as
always, I/O reads are bad for performance.

Therefore, restrict the readback to the chipsets that need it, or, for
debugging purposes, when we are running with hpet=verbose.
Signed-off-by: default avatarThomas Gleixner <tglx@linutronix.de>
Acked-by: default avatarVenkatesh Pallipadi <venki@google.com>
LKML-Reference: <20100225185348.GA9674@linux-os.sc.intel.com>
Signed-off-by: default avatarH. Peter Anvin <hpa@zytor.com>
parent 1d16b0f2
......@@ -68,6 +68,7 @@ extern unsigned long force_hpet_address;
extern u8 hpet_blockid;
extern int hpet_force_user;
extern u8 hpet_msi_disable;
extern u8 hpet_readback_cmp;
extern int is_hpet_enabled(void);
extern int hpet_enable(void);
extern void hpet_disable(void);
......
......@@ -36,6 +36,7 @@
unsigned long hpet_address;
u8 hpet_blockid; /* OS timer block num */
u8 hpet_msi_disable;
u8 hpet_readback_cmp;
#ifdef CONFIG_PCI_MSI
static unsigned long hpet_num_timers;
......@@ -395,19 +396,23 @@ static int hpet_next_event(unsigned long delta,
* at that point and we would wait for the next hpet interrupt
* forever. We found out that reading the CMP register back
* forces the transfer so we can rely on the comparison with
* the counter register below. If the read back from the
* compare register does not match the value we programmed
* then we might have a real hardware problem. We can not do
* much about it here, but at least alert the user/admin with
* a prominent warning.
* An erratum on some chipsets (ICH9,..), results in comparator read
* immediately following a write returning old value. Workaround
* for this is to read this value second time, when first
* read returns old value.
* the counter register below.
*
* That works fine on those ATI chipsets, but on newer Intel
* chipsets (ICH9...) this triggers due to an erratum: Reading
* the comparator immediately following a write is returning
* the old value.
*
* We restrict the read back to the affected ATI chipsets (set
* by quirks) and also run it with hpet=verbose for debugging
* purposes.
*/
if (unlikely((u32)hpet_readl(HPET_Tn_CMP(timer)) != cnt)) {
WARN_ONCE(hpet_readl(HPET_Tn_CMP(timer)) != cnt,
KERN_WARNING "hpet: compare register read back failed.\n");
if (hpet_readback_cmp || hpet_verbose) {
u32 cmp = hpet_readl(HPET_Tn_CMP(timer));
if (cmp != cnt)
printk_once(KERN_WARNING
"hpet: compare register read back failed.\n");
}
return (s32)(hpet_readl(HPET_COUNTER) - cnt) >= 0 ? -ETIME : 0;
......
......@@ -495,10 +495,15 @@ void force_hpet_resume(void)
/*
* HPET MSI on some boards (ATI SB700/SB800) has side effect on
* floppy DMA. Disable HPET MSI on such platforms.
*
* Also force the read back of the CMP register in hpet_next_event()
* to work around the problem that the CMP register write seems to be
* delayed. See hpet_next_event() for details.
*/
static void force_disable_hpet_msi(struct pci_dev *unused)
{
hpet_msi_disable = 1;
hpet_readback_cmp = 1;
}
DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_ATI, PCI_DEVICE_ID_ATI_SBX00_SMBUS,
......