staging: comedi: pcl812: tidy up the analog input (*insn_read)
For aesthetics, move this function out of the async command support code. For safety, the INT request (end-of-conversion flag) should be cleared before doing each conversion and after the final data sample is read. The driver currently does not do this. Refactor the function a bit so it's more like the pcl818 and pcl816 drivers and use common code to clear the flag for a timeout and after the last sample. Do a bit of other tidying up during the move. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>