Commit 3930d730 authored by Long Li's avatar Long Li Committed by Martin K. Petersen

scsi: storvsc: use default I/O timeout handler for FC devices

FC disks issue I/O directly to the host storage port driver, this is
diffirent to VHD disks where I/O is virtualized and timeout is handled
by the host VSP (Virtualization Service Provider).

FC disks are usually setup in a multipath system, and they don't want to
reset timer on I/O timeout. Timeout is detected by multipath as a good
time to failover and recover.
Signed-off-by: default avatarLong Li <longli@microsoft.com>
Signed-off-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>
parent 5cc973f0
...@@ -1495,6 +1495,10 @@ static int storvsc_host_reset_handler(struct scsi_cmnd *scmnd) ...@@ -1495,6 +1495,10 @@ static int storvsc_host_reset_handler(struct scsi_cmnd *scmnd)
*/ */
static enum blk_eh_timer_return storvsc_eh_timed_out(struct scsi_cmnd *scmnd) static enum blk_eh_timer_return storvsc_eh_timed_out(struct scsi_cmnd *scmnd)
{ {
#if IS_ENABLED(CONFIG_SCSI_FC_ATTRS)
if (scmnd->device->host->transportt == fc_transport_template)
return fc_eh_timed_out(scmnd);
#endif
return BLK_EH_RESET_TIMER; return BLK_EH_RESET_TIMER;
} }
......