Input: ti_am335x_tsc - interchange touchscreen and ADC steps
This patch makes the initial changes required to workaround TSC-false pen-up interrupts. It is required to implement these changes in order to remove udelay in the TSC interrupt handler and false pen-up events. The charge step is to be executed immediately after sampling X+. Hence TSC is made to use higher numbered steps (steps 5 to 16 for 5 co-ordinate readouts, 4 wire TSC configuration) and ADC to use lower ones. Further X co-ordinate readouts must be the last to be sampled, thus co-ordinates are sampled in the order Y-Z-X. Signed-off-by: Brad Griffis <bgriffis@ti.com> [vigneshr@ti.com: Ported the patch from v3.12 to v3.19rc1] Signed-off-by: Vignesh R <vigneshr@ti.com> Acked-by: Jonathan Cameron <jic23@kernel.org> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>