Commit c0fe18ba authored by Russell King's avatar Russell King

ARM: l2c: move errata configuration options to arch/arm/mm/Kconfig

Move the L2C-310 errata configuration options to arch/arm/mm/Kconfig
along side the option which enables support for this device.
Signed-off-by: default avatarRussell King <rmk+kernel@arm.linux.org.uk>
parent 0493aef4
...@@ -1230,19 +1230,6 @@ config ARM_ERRATA_742231 ...@@ -1230,19 +1230,6 @@ config ARM_ERRATA_742231
register of the Cortex-A9 which reduces the linefill issuing register of the Cortex-A9 which reduces the linefill issuing
capabilities of the processor. capabilities of the processor.
config PL310_ERRATA_588369
bool "PL310 errata: Clean & Invalidate maintenance operations do not invalidate clean lines"
depends on CACHE_L2X0
help
The PL310 L2 cache controller implements three types of Clean &
Invalidate maintenance operations: by Physical Address
(offset 0x7F0), by Index/Way (0x7F8) and by Way (0x7FC).
They are architecturally defined to behave as the execution of a
clean operation followed immediately by an invalidate operation,
both performing to the same memory location. This functionality
is not correctly implemented in PL310 as clean lines are not
invalidated as a result of these operations.
config ARM_ERRATA_643719 config ARM_ERRATA_643719
bool "ARM errata: LoUIS bit field in CLIDR register is incorrect" bool "ARM errata: LoUIS bit field in CLIDR register is incorrect"
depends on CPU_V7 && SMP depends on CPU_V7 && SMP
...@@ -1265,17 +1252,6 @@ config ARM_ERRATA_720789 ...@@ -1265,17 +1252,6 @@ config ARM_ERRATA_720789
tables. The workaround changes the TLB flushing routines to invalidate tables. The workaround changes the TLB flushing routines to invalidate
entries regardless of the ASID. entries regardless of the ASID.
config PL310_ERRATA_727915
bool "PL310 errata: Background Clean & Invalidate by Way operation can cause data corruption"
depends on CACHE_L2X0
help
PL310 implements the Clean & Invalidate by Way L2 cache maintenance
operation (offset 0x7FC). This operation runs in background so that
PL310 can handle normal accesses while it is in progress. Under very
rare circumstances, due to this erratum, write data can be lost when
PL310 treats a cacheable write transaction during a Clean &
Invalidate by Way operation.
config ARM_ERRATA_743622 config ARM_ERRATA_743622
bool "ARM errata: Faulty hazard checking in the Store Buffer may lead to data corruption" bool "ARM errata: Faulty hazard checking in the Store Buffer may lead to data corruption"
depends on CPU_V7 depends on CPU_V7
...@@ -1301,21 +1277,6 @@ config ARM_ERRATA_751472 ...@@ -1301,21 +1277,6 @@ config ARM_ERRATA_751472
operation is received by a CPU before the ICIALLUIS has completed, operation is received by a CPU before the ICIALLUIS has completed,
potentially leading to corrupted entries in the cache or TLB. potentially leading to corrupted entries in the cache or TLB.
config PL310_ERRATA_753970
bool "PL310 errata: cache sync operation may be faulty"
depends on CACHE_PL310
help
This option enables the workaround for the 753970 PL310 (r3p0) erratum.
Under some condition the effect of cache sync operation on
the store buffer still remains when the operation completes.
This means that the store buffer is always asked to drain and
this prevents it from merging any further writes. The workaround
is to replace the normal offset of cache sync operation (0x730)
by another offset targeting an unmapped PL310 register 0x740.
This has the same effect as the cache sync operation: store buffer
drain and waiting for all buffers empty.
config ARM_ERRATA_754322 config ARM_ERRATA_754322
bool "ARM errata: possible faulty MMU translations following an ASID switch" bool "ARM errata: possible faulty MMU translations following an ASID switch"
depends on CPU_V7 depends on CPU_V7
...@@ -1364,18 +1325,6 @@ config ARM_ERRATA_764369 ...@@ -1364,18 +1325,6 @@ config ARM_ERRATA_764369
relevant cache maintenance functions and sets a specific bit relevant cache maintenance functions and sets a specific bit
in the diagnostic control register of the SCU. in the diagnostic control register of the SCU.
config PL310_ERRATA_769419
bool "PL310 errata: no automatic Store Buffer drain"
depends on CACHE_L2X0
help
On revisions of the PL310 prior to r3p2, the Store Buffer does
not automatically drain. This can cause normal, non-cacheable
writes to be retained when the memory system is idle, leading
to suboptimal I/O performance for drivers using coherent DMA.
This option adds a write barrier to the cpu_idle loop so that,
on systems with an outer cache, the store buffer is drained
explicitly.
config ARM_ERRATA_775420 config ARM_ERRATA_775420
bool "ARM errata: A data cache maintenance operation which aborts, might lead to deadlock" bool "ARM errata: A data cache maintenance operation which aborts, might lead to deadlock"
depends on CPU_V7 depends on CPU_V7
......
...@@ -897,6 +897,57 @@ config CACHE_PL310 ...@@ -897,6 +897,57 @@ config CACHE_PL310
This option enables optimisations for the PL310 cache This option enables optimisations for the PL310 cache
controller. controller.
config PL310_ERRATA_588369
bool "PL310 errata: Clean & Invalidate maintenance operations do not invalidate clean lines"
depends on CACHE_L2X0
help
The PL310 L2 cache controller implements three types of Clean &
Invalidate maintenance operations: by Physical Address
(offset 0x7F0), by Index/Way (0x7F8) and by Way (0x7FC).
They are architecturally defined to behave as the execution of a
clean operation followed immediately by an invalidate operation,
both performing to the same memory location. This functionality
is not correctly implemented in PL310 as clean lines are not
invalidated as a result of these operations.
config PL310_ERRATA_727915
bool "PL310 errata: Background Clean & Invalidate by Way operation can cause data corruption"
depends on CACHE_L2X0
help
PL310 implements the Clean & Invalidate by Way L2 cache maintenance
operation (offset 0x7FC). This operation runs in background so that
PL310 can handle normal accesses while it is in progress. Under very
rare circumstances, due to this erratum, write data can be lost when
PL310 treats a cacheable write transaction during a Clean &
Invalidate by Way operation.
config PL310_ERRATA_753970
bool "PL310 errata: cache sync operation may be faulty"
depends on CACHE_PL310
help
This option enables the workaround for the 753970 PL310 (r3p0) erratum.
Under some condition the effect of cache sync operation on
the store buffer still remains when the operation completes.
This means that the store buffer is always asked to drain and
this prevents it from merging any further writes. The workaround
is to replace the normal offset of cache sync operation (0x730)
by another offset targeting an unmapped PL310 register 0x740.
This has the same effect as the cache sync operation: store buffer
drain and waiting for all buffers empty.
config PL310_ERRATA_769419
bool "PL310 errata: no automatic Store Buffer drain"
depends on CACHE_L2X0
help
On revisions of the PL310 prior to r3p2, the Store Buffer does
not automatically drain. This can cause normal, non-cacheable
writes to be retained when the memory system is idle, leading
to suboptimal I/O performance for drivers using coherent DMA.
This option adds a write barrier to the cpu_idle loop so that,
on systems with an outer cache, the store buffer is drained
explicitly.
config CACHE_TAUROS2 config CACHE_TAUROS2
bool "Enable the Tauros2 L2 cache controller" bool "Enable the Tauros2 L2 cache controller"
depends on (ARCH_DOVE || ARCH_MMP || CPU_PJ4) depends on (ARCH_DOVE || ARCH_MMP || CPU_PJ4)
......
Markdown is supported