Commit e56270f6 authored by Yuval Mintz's avatar Yuval Mintz Committed by David S. Miller

bnx2x: Warn about grc timeouts in register dump

There are several scenarios where taking a register dump from a device
might log benign GRC timeout attentions to system logs.
Most common of those is when taking the dump from a 2-port device.

Sadly, there's no easy way to mask the problematic attentions during the
flow - Changing this behvaior would require a firmware update.
For now, simply warn users to ignore the warnings.
Signed-off-by: default avatarYuval Mintz <Yuval.Mintz@qlogic.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent e5d3a51c
...@@ -981,6 +981,11 @@ static void bnx2x_get_regs(struct net_device *dev, ...@@ -981,6 +981,11 @@ static void bnx2x_get_regs(struct net_device *dev,
memcpy(p, &dump_hdr, sizeof(struct dump_header)); memcpy(p, &dump_hdr, sizeof(struct dump_header));
p += dump_hdr.header_size + 1; p += dump_hdr.header_size + 1;
/* This isn't really an error, but since attention handling is going
* to print the GRC timeouts using this macro, we use the same.
*/
BNX2X_ERR("Generating register dump. Might trigger harmless GRC timeouts\n");
/* Actually read the registers */ /* Actually read the registers */
__bnx2x_get_regs(bp, p); __bnx2x_get_regs(bp, p);
......