1. 31 Aug, 2007 18 commits
  2. 30 Aug, 2007 21 commits
  3. 29 Aug, 2007 1 commit
    • Christian Krafft's avatar
      [POWERPC] spu_manage: fix spu_unit_number for celleb device tree · aac2e684
      Christian Krafft authored
      This fixes a regression introduced with 2.6.23-rc4 after on some
      confusion about the device tree interfaces.
      
      IBM QS21 device trees provide "physical-id", so we changed the code to
      run on that and remain compatible with all IBM machines.
      
      However, the Toshiba Celleb device tree provides the "unit-id" property,
      which was in the Linux code, but never used in this way on IBM hardware.
      
      Legacy device tree used the reg property for the physical id of an spe.
      This patch fixes find_spu_unit_number to look for the spu id in that order.
      The length is checked to avoid misinterpretation in case the attributes
      unit-id or reg do not contain the id.
      Signed-off-by: default avatarChristian Krafft <krafft@de.ibm.com>
      Signed-off-by: default avatarArnd Bergmann <arnd.bergmann@de.ibm.com>
      Cc: Jeremy Kerr <jk@ozlabs.org>
      aac2e684