Luis Soares authored
The test case creates two temporary tables, then closes the connection, waits for it to disconnect, then syncs the slave with the master, checks for remaining opened temporary tables on slave (which should be 0) and finally drops the used database (mysqltest). Unfortunately, sometimes, the test fails with one open table on the slave. This seems to be caused by the fact that waiting for the connection to be closed is not sufficient. The test needs to wait for the DROP event to be logged and only then synchronize the slave with the master and proceed with the check. This is caused by the asynchronous nature of the disconnect wrt binlogging of the DROP temporary table statement. We fix this by deploying a call to wait_for_binlog_event.inc on the test case, which makes execution to wait for the DROP temp tables event before synchronizing master and slave.
3c916057