Commit b19cf78c authored by unknown's avatar unknown

Merge gbichot@bk-internal.mysql.com:/home/bk/mysql-4.0

into mysql.com:/home/mysql_src/mysql-4.0
parents 203c4674 f1446eac
......@@ -843,7 +843,7 @@ void MYSQL_LOG::new_file(bool need_lock)
We log the whole file name for log file as the user may decide
to change base names at some point.
*/
THD* thd = current_thd;
THD* thd = current_thd; /* may be 0 if we are reacting to SIGHUP */
Rotate_log_event r(thd,new_name+dirname_length(new_name));
r.set_log_pos(this);
......@@ -852,7 +852,7 @@ void MYSQL_LOG::new_file(bool need_lock)
the slave running with log-bin, we set the flag on rotate
event to prevent infinite log rotation loop
*/
if (thd->slave_thread)
if (thd && thd->slave_thread)
r.flags|= LOG_EVENT_FORCED_ROTATE_F;
r.write(&log_file);
bytes_written += r.get_event_len();
......
......@@ -128,7 +128,12 @@ Log_event::Log_event(THD* thd_arg, uint16 flags_arg, bool using_trans)
(thd->options & (OPTION_NOT_AUTOCOMMIT | OPTION_BEGIN)));
}
/*
This minimal constructor is for when you are not even sure that there is a
valid THD. For example in the server when we are shutting down or flushing
logs after receiving a SIGHUP (then we must write a Rotate to the binlog but
we have no THD, so we need this minimal constructor).
*/
Log_event::Log_event()
:temp_buf(0), exec_time(0), cached_event_len(0), flags(0), cache_stmt(0),
thd(0)
......
......@@ -607,7 +607,7 @@ class Rotate_log_event: public Log_event
Rotate_log_event(THD* thd_arg, const char* new_log_ident_arg,
uint ident_len_arg = 0,
ulonglong pos_arg = LOG_EVENT_OFFSET)
:Log_event(thd_arg,0,0), new_log_ident(new_log_ident_arg),
:Log_event(), new_log_ident(new_log_ident_arg),
pos(pos_arg),ident_len(ident_len_arg ? ident_len_arg :
(uint) strlen(new_log_ident_arg)), alloced(0)
{}
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment