Bug #13601: Wrong int type for bit
The wrong value was being reported as the field_length for BIT fields, resulting in confusion for at least Connector/J. The field_length is now always the number of bits in the field, as it should be. mysql-test/r/type_bit.result: Add new results mysql-test/r/type_bit_innodb.result: Add new results mysql-test/t/type_bit.test: Add new regression test mysql-test/t/type_bit_innodb.test: Add new regression test sql/field.cc: Fix Field_bit->field_length to actually report the display width, and store the bytes stored in the rec in the new bytes_in_rec member. sql/field.h: Fix Field_bit::field_length to store the correct value, adding Field_bit::bytes_in_rec to remember the number of bytes used for storing the value. Remove Field_bit_as_char::create_length, as it is now redundant. sql/ha_ndbcluster.cc: Handle field_length of Field_bit actually being the display width (# of bits). sql/key.cc: Fix inappropriate use of field->field_length for BIT field.