......@@ -227,3 +227,86 @@ UPDATE t1 SET b = '%s%s%s%s%s%s%s%s%s%s%s%s%s%s' WHERE a = 'a' LIMIT 1;
Warnings:
Warning 1592 Statement is not safe to log in statement format.
DROP TABLE t1;
DROP TABLE IF EXISTS t1, t2;
CREATE TABLE t1(i INT PRIMARY KEY);
CREATE TABLE t2(i INT PRIMARY KEY);
CREATE TABLE t3(i INT, ch CHAR(50));
"Should issue message Statement is not safe to log in statement format."
INSERT INTO t1 SELECT * FROM t2 LIMIT 1;
Warnings:
Warning 1592 Statement is not safe to log in statement format.
CREATE FUNCTION func6()
RETURNS INT
BEGIN
INSERT INTO t1 VALUES (10);
INSERT INTO t1 VALUES (11);
INSERT INTO t1 VALUES (12);
RETURN 0;
END|
"Should issue message Statement is not safe to log in statement format only once"
INSERT INTO t3 VALUES(func6(), UUID());
Warnings:
Warning 1592 Statement is not safe to log in statement format.
"Check whether SET @@SQL_LOG_BIN = 0/1 doesn't work in substatements"
CREATE FUNCTION fun_check_log_bin() RETURNS INT
BEGIN
SET @@SQL_LOG_BIN = 0;
INSERT INTO t1 VALUES(@@global.sync_binlog);
RETURN 100;
END|
"One unsafe warning should be issued in the following statement"
SELECT fun_check_log_bin();
fun_check_log_bin()
100
Warnings:
Warning 1592 Statement is not safe to log in statement format.
"SQL_LOG_BIN should be ON still"
SHOW VARIABLES LIKE "SQL_LOG_BIN";
Variable_name Value
sql_log_bin ON
set @save_log_bin = @@SESSION.SQL_LOG_BIN;
set @@SESSION.SQL_LOG_BIN = 0;
"Should NOT have any warning message issued in the following statements"
INSERT INTO t1 SELECT * FROM t2 LIMIT 1;
DROP TABLE t1,t2;
"Should NOT have any warning message issued in the following func7() and trig"
CREATE TABLE t1 (a INT);
CREATE TABLE t2 (a CHAR(40));
CREATE TABLE trigger_table (a CHAR(7));
CREATE FUNCTION func7()
RETURNS INT
BEGIN
INSERT INTO t1 VALUES (@@global.sync_binlog);
INSERT INTO t1 VALUES (@@session.insert_id);
INSERT INTO t2 SELECT UUID();
INSERT INTO t2 VALUES (@@session.sql_mode);
INSERT INTO t2 VALUES (@@global.init_slave);
RETURN 0;
END|
SHOW VARIABLES LIKE "SQL_LOG_BIN";
Variable_name Value
sql_log_bin OFF
SELECT func7();
func7()
0
---- Insert from trigger ----
CREATE TRIGGER trig
BEFORE INSERT ON trigger_table
FOR EACH ROW
BEGIN
INSERT INTO t1 VALUES (@@global.sync_binlog);
INSERT INTO t1 VALUES (@@session.insert_id);
INSERT INTO t1 VALUES (@@global.auto_increment_increment);
INSERT INTO t2 SELECT UUID();
INSERT INTO t2 VALUES (@@session.sql_mode);
INSERT INTO t2 VALUES (@@global.init_slave);
INSERT INTO t2 VALUES (@@hostname);
END|
INSERT INTO trigger_table VALUES ('bye.');
DROP FUNCTION fun_check_log_bin;
DROP FUNCTION func6;
DROP FUNCTION func7;
DROP TRIGGER trig;
DROP TABLE t1, t2, t3, trigger_table;
set @@SESSION.SQL_LOG_BIN = @save_log_bin;
"End of tests"
......@@ -8,6 +8,7 @@
# executed cannot be determined (e.g., INSERT DELAYED). Such
# statements should be marked unsafe. All unsafe statements should
# give a warning.
# Yet the warning/error message isn't issued when SQL_LOG_BIN is turned off.
#
# This test verifies that a warning is generated for statements that
# should be unsafe, when they are executed under statement mode
......@@ -32,14 +33,19 @@
# We try to insert the variables that should not be unsafe into a
# table, and verify that *no* warning is issued.
#
#
# Execute a unsafe statement calling a trigger or stored function
# or neither when SQL_LOG_BIN is turned ON, a warning/error should be issued
# Execute a unsafe statement calling a trigger or stored function
# or neither when @@SQL_LOG_BIN is turned OFF,
# no warning/error is issued
# ==== Related bugs and worklogs ====
#
# WL#3339: Issue warnings when statement-based replication may fail
# BUG#31168: @@hostname does not replicate
# BUG#34732: mysqlbinlog does not print default values for auto_increment variables
# BUG#34768: nondeterministic INSERT using LIMIT logged in stmt mode if binlog_format=mixed
#
# BUG#41980, SBL, INSERT .. SELECT .. LIMIT = ERROR, even when @@SQL_LOG_BIN is 0
#
# ==== Related test cases ====
#
......@@ -271,3 +277,96 @@ INSERT INTO t1 VALUES ('a','b');
UPDATE t1 SET b = '%s%s%s%s%s%s%s%s%s%s%s%s%s%s' WHERE a = 'a' LIMIT 1;
DROP TABLE t1;
#
#For bug#41980, SBL, INSERT .. SELECT .. LIMIT = ERROR, even when @@SQL_LOG_BIN is 0
#
--disable_warnings
DROP TABLE IF EXISTS t1, t2;
--enable_warnings
CREATE TABLE t1(i INT PRIMARY KEY);
CREATE TABLE t2(i INT PRIMARY KEY);
CREATE TABLE t3(i INT, ch CHAR(50));
--echo "Should issue message Statement is not safe to log in statement format."
INSERT INTO t1 SELECT * FROM t2 LIMIT 1;
DELIMITER |;
CREATE FUNCTION func6()
RETURNS INT
BEGIN
INSERT INTO t1 VALUES (10);
INSERT INTO t1 VALUES (11);
INSERT INTO t1 VALUES (12);
RETURN 0;
END|
DELIMITER ;|
--echo "Should issue message Statement is not safe to log in statement format only once"
INSERT INTO t3 VALUES(func6(), UUID());
--echo "Check whether SET @@SQL_LOG_BIN = 0/1 doesn't work in substatements"
DELIMITER |;
CREATE FUNCTION fun_check_log_bin() RETURNS INT
BEGIN
SET @@SQL_LOG_BIN = 0;
INSERT INTO t1 VALUES(@@global.sync_binlog);
RETURN 100;
END|
DELIMITER ;|
--echo "One unsafe warning should be issued in the following statement"
SELECT fun_check_log_bin();
--echo "SQL_LOG_BIN should be ON still"
SHOW VARIABLES LIKE "SQL_LOG_BIN";
set @save_log_bin = @@SESSION.SQL_LOG_BIN;
set @@SESSION.SQL_LOG_BIN = 0;
--echo "Should NOT have any warning message issued in the following statements"
INSERT INTO t1 SELECT * FROM t2 LIMIT 1;
DROP TABLE t1,t2;
--echo "Should NOT have any warning message issued in the following func7() and trig"
CREATE TABLE t1 (a INT);
CREATE TABLE t2 (a CHAR(40));
CREATE TABLE trigger_table (a CHAR(7));
DELIMITER |;
CREATE FUNCTION func7()
RETURNS INT
BEGIN
INSERT INTO t1 VALUES (@@global.sync_binlog);
INSERT INTO t1 VALUES (@@session.insert_id);
INSERT INTO t2 SELECT UUID();
INSERT INTO t2 VALUES (@@session.sql_mode);
INSERT INTO t2 VALUES (@@global.init_slave);
RETURN 0;
END|
DELIMITER ;|
SHOW VARIABLES LIKE "SQL_LOG_BIN";
SELECT func7();
--echo ---- Insert from trigger ----
DELIMITER |;
CREATE TRIGGER trig
BEFORE INSERT ON trigger_table
FOR EACH ROW
BEGIN
INSERT INTO t1 VALUES (@@global.sync_binlog);
INSERT INTO t1 VALUES (@@session.insert_id);
INSERT INTO t1 VALUES (@@global.auto_increment_increment);
INSERT INTO t2 SELECT UUID();
INSERT INTO t2 VALUES (@@session.sql_mode);
INSERT INTO t2 VALUES (@@global.init_slave);
INSERT INTO t2 VALUES (@@hostname);
END|
DELIMITER ;|
INSERT INTO trigger_table VALUES ('bye.');
#clean up
DROP FUNCTION fun_check_log_bin;
DROP FUNCTION func6;
DROP FUNCTION func7;
DROP TRIGGER trig;
DROP TABLE t1, t2, t3, trigger_table;
set @@SESSION.SQL_LOG_BIN = @save_log_bin;
--echo "End of tests"
......@@ -110,6 +110,7 @@ static void sys_default_init_connect(THD*, enum_var_type type);
static bool sys_update_init_slave(THD*, set_var*);
static void sys_default_init_slave(THD*, enum_var_type type);
static bool set_option_bit(THD *thd, set_var *var);
static bool set_option_log_bin_bit(THD *thd, set_var *var);
static bool set_option_autocommit(THD *thd, set_var *var);
static int check_log_update(THD *thd, set_var *var);
static bool set_log_update(THD *thd, set_var *var);
......@@ -731,7 +732,7 @@ static sys_var_thd_bit sys_log_update(&vars, "sql_log_update",
OPTION_BIN_LOG);
static sys_var_thd_bit sys_log_binlog(&vars, "sql_log_bin",
check_log_update,
set_option_bit,
set_option_log_bin_bit,
OPTION_BIN_LOG);
static sys_var_thd_bit sys_sql_warnings(&vars, "sql_warnings", 0,
set_option_bit,
......@@ -2963,6 +2964,16 @@ static bool set_option_bit(THD *thd, set_var *var)
return 0;
}
/*
Functions to be only used to update thd->options OPTION_BIN_LOG bit
*/
static bool set_option_log_bin_bit(THD *thd, set_var *var)
{
set_option_bit(thd, var);
if (!thd->in_sub_stmt)
thd->sql_log_bin_toplevel= thd->options & OPTION_BIN_LOG;
return 0;
}
static bool set_option_autocommit(THD *thd, set_var *var)
{
......
......@@ -538,6 +538,7 @@ THD::THD()
Open_tables_state(refresh_version), rli_fake(0),
lock_id(&main_lock_id),
user_time(0), in_sub_stmt(0),
sql_log_bin_toplevel(false),
binlog_table_maps(0), binlog_flags(0UL),
table_map_for_update(0),
arg_of_last_insert_id_function(FALSE),
......@@ -787,6 +788,7 @@ void THD::init(void)
update_charset();
reset_current_stmt_binlog_row_based();
bzero((char *) &status_var, sizeof(status_var));
sql_log_bin_toplevel= options & OPTION_BIN_LOG;
}
......@@ -3662,7 +3664,7 @@ int THD::binlog_query(THD::enum_binlog_query_type qtype, char const *query_arg,
If we are in statement mode and trying to log an unsafe statement,
we should print a warning.
*/
if (lex->is_stmt_unsafe() &&
if (sql_log_bin_toplevel && lex->is_stmt_unsafe() &&
variables.binlog_format == BINLOG_FORMAT_STMT)
{
push_warning(this, MYSQL_ERROR::WARN_LEVEL_WARN,
......
......@@ -1350,6 +1350,8 @@ class THD :public Statement,
/* <> 0 if we are inside of trigger or stored function. */
uint in_sub_stmt;
/* TRUE when the current top has SQL_LOG_BIN ON */
bool sql_log_bin_toplevel;
/* container for handler's private per-connection data */
Ha_data ha_data[MAX_HA];
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment