Commit 13d39cf2 authored by Claes Sjofors's avatar Claes Sjofors

Sinamics_G120_Tgm1, trend settings corrected (refs #26)

parent 7a9df1d5
......@@ -6419,14 +6419,14 @@ Volume Siemens $ClassVolume 0.0.250.3
Attr Super.StatusWordSW.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO3IoModule.I_SW"
Attr Super.ActSpeed.Description = "Actual Value, from converter"
Attr Super.ActSpeed.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO3IoModule.I_ACT"
Attr Super.ActSpeed.PresMinLimit = 1.000000e+02
Attr Super.ActSpeed.DefTrend = "_O0.0.0.0:0"
Attr Super.ActSpeed.PresMaxLimit = 1.000000e+02
Attr Super.ActSpeed.DefTrend = "Siemens:Class-Sinamics_G120_Tgm1-Template.Super.TrendActSpeed"
Attr Super.ControlWordCW.Description = "Control Word, to converter"
Attr Super.ControlWordCW.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO3IoModule.O_CW"
Attr Super.RefSpeed.Description = "Reference Value, to converter"
Attr Super.RefSpeed.SigChanCon = "$IoConnect:BaseComponent-Class-BaseFcPPO3IoModule.O_REF"
Attr Super.RefSpeed.PresMinLimit = 1.000000e+02
Attr Super.RefSpeed.DefTrend = "_O0.0.0.0:0"
Attr Super.RefSpeed.PresMaxLimit = 1.000000e+02
Attr Super.RefSpeed.DefTrend = "Siemens:Class-Sinamics_G120_Tgm1-Template.Super.TrendRefSpeed"
Attr Super.PowerUpTime = 1.500000e+01
Attr Super.AlarmLocalMod = "Frequency converter is in local mode, "
Attr Super.AlarmTripped = "Frequency converter tripped, reset is required"
......@@ -6435,14 +6435,14 @@ Volume Siemens $ClassVolume 0.0.250.3
Attr Super.AlarmConnection = "No connection"
Attr Super.DefTrend = "Siemens:Class-Sinamics_G120_Tgm1-Template.Super.PlotGroup"
Attr Super.TrendActSpeed.Multiple = 1
Attr Super.TrendActSpeed.DataName = "Siemens:Class-Sinamics_G120_Tgm1-Template.Super.ActSpeed"
Attr Super.TrendActSpeed.DataName = "Siemens:Class-Sinamics_G120_Tgm1-Template.Super.ActSpeed.ActualValue"
Attr Super.TrendActSpeed.StorageTime = 239
Attr Super.TrendActSpeed.BufferStatus[0] = 1
Attr Super.TrendActSpeed.BufferStatus[1] = 1
Attr Super.TrendActSpeed.NoOfBuffers = 2
Attr Super.TrendActSpeed.NoOfBufElement = 239
Attr Super.TrendRefSpeed.Multiple = 1
Attr Super.TrendRefSpeed.DataName = "Siemens:Class-Sinamics_G120_Tgm1-Template.Super.RefSpeed"
Attr Super.TrendRefSpeed.DataName = "Siemens:Class-Sinamics_G120_Tgm1-Template.Super.RefSpeed.ActualValue"
Attr Super.TrendRefSpeed.StorageTime = 239
Attr Super.TrendRefSpeed.BufferStatus[0] = 1
Attr Super.TrendRefSpeed.BufferStatus[1] = 1
......