Commit c914b04b authored by claes's avatar claes

*** empty log message ***

parent 52c888be
......@@ -11553,14 +11553,14 @@ ResTrip = trp
The attribute below must always placed last in this PlcPgm."
EndBody
EndObject
Object PowerOn ContactorFo 239
Object PowerOn BaseContactorFo 239
Body RtBody
Attr PlcConnect = "$PlcConnect:ABB-Class-ABB_ACS800Pump1.Contactor"
EndBody
Body DevBody
Buffer PlcNode
Attr object_type = 11
Attr cid = "BaseComponent:Class-ContactorFo"
Attr cid = "BaseComponent:Class-BaseContactorFo"
Attr oid = "ABB:Class-ABB_ACS800Pump1Fo-Code-W-PowerOn"
Attr x = 2.400000e+00
Attr y = -2.725000e+00
......@@ -11591,14 +11591,14 @@ The attribute below must always placed last in this PlcPgm."
EndBuffer
EndBody
EndObject
Object SafetySwitch SafetySwitchFo 244
Object SafetySwitch BaseSafetySwitchFo 244
Body RtBody
Attr PlcConnect = "$PlcConnect:ABB-Class-ABB_ACS800Pump1.SafetySwitch"
EndBody
Body DevBody
Buffer PlcNode
Attr object_type = 11
Attr cid = "BaseComponent:Class-SafetySwitchFo"
Attr cid = "BaseComponent:Class-BaseSafetySwitchFo"
Attr oid = "ABB:Class-ABB_ACS800Pump1Fo-Code-W-SafetySwitch"
Attr x = 6.000000e-01
Attr y = -3.075000e+00
......@@ -11929,14 +11929,14 @@ Yellow = Warning"
Attr Text = "Mode"
EndBody
EndObject
Object CircuitBreaker CircuitBreakerFo 275
Object CircuitBreaker BaseCircuitBreakerFo 275
Body RtBody
Attr PlcConnect = "$PlcConnect:ABB-Class-ABB_ACS800Pump1.CircuitBreaker"
EndBody
Body DevBody
Buffer PlcNode
Attr object_type = 11
Attr cid = "BaseComponent:Class-CircuitBreakerFo"
Attr cid = "BaseComponent:Class-BaseCircuitBreakerFo"
Attr oid = "ABB:Class-ABB_ACS800Pump1Fo-Code-W-CircuitBreaker"
Attr x = 6.000000e-01
Attr y = -3.275000e+00
......@@ -17619,7 +17619,7 @@ if Op reset converter."
Body SysBody
Attr PgmName = "Contactor"
Attr Flags = 131080
Attr TypeRef = "BaseComponent:Class-Contactor"
Attr TypeRef = "BaseComponent:Class-BaseContactor"
EndBody
EndObject
Object ACS800 $Attribute 60
......@@ -17640,7 +17640,7 @@ if Op reset converter."
Body SysBody
Attr PgmName = "SafetySwitch"
Attr Flags = 131080
Attr TypeRef = "BaseComponent:Class-SafetySwitch"
Attr TypeRef = "BaseComponent:Class-BaseSafetySwitch"
EndBody
EndObject
Object CastMotor $Attribute 63
......@@ -17654,7 +17654,7 @@ if Op reset converter."
Body SysBody
Attr PgmName = "Motor"
Attr Flags = 131080
Attr TypeRef = "BaseComponent:Class-Motor"
Attr TypeRef = "BaseComponent:Class-BaseMotor"
EndBody
EndObject
Object CastPump $Attribute 74
......@@ -21982,14 +21982,14 @@ ResTrip = trp
The attribute below must always placed last in this PlcPgm."
EndBody
EndObject
Object PowerOn ContactorFo 1481
Object PowerOn BaseContactorFo 1481
Body RtBody
Attr PlcConnect = "$PlcConnect:ABB-Class-ABB_ACS800Pump2.Contactor"
EndBody
Body DevBody
Buffer PlcNode
Attr object_type = 11
Attr cid = "BaseComponent:Class-ContactorFo"
Attr cid = "BaseComponent:Class-BaseContactorFo"
Attr oid = "ABB:Class-ABB_ACS800Pump2Fo-Code-W-PowerOn"
Attr x = 2.400000e+00
Attr y = -2.725000e+00
......@@ -22020,14 +22020,14 @@ The attribute below must always placed last in this PlcPgm."
EndBuffer
EndBody
EndObject
Object SafetySwitch SafetySwitchFo 1483
Object SafetySwitch BaseSafetySwitchFo 1483
Body RtBody
Attr PlcConnect = "$PlcConnect:ABB-Class-ABB_ACS800Pump2.SafetySwitch"
EndBody
Body DevBody
Buffer PlcNode
Attr object_type = 11
Attr cid = "BaseComponent:Class-SafetySwitchFo"
Attr cid = "BaseComponent:Class-BaseSafetySwitchFo"
Attr oid = "ABB:Class-ABB_ACS800Pump2Fo-Code-W-SafetySwitch"
Attr x = 6.000000e-01
Attr y = -3.075000e+00
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment