1. 06 Jan, 2020 14 commits
  2. 04 Jan, 2020 4 commits
  3. 03 Jan, 2020 11 commits
  4. 02 Jan, 2020 5 commits
  5. 31 Dec, 2019 1 commit
    • Tobias Klauser's avatar
      internal/poll: use correct fcntl implementations · bbd25d26
      Tobias Klauser authored
      Use the libc fcntl (via syscall.fcntl) on aix and solaris like it is
      already done for darwin.
      
      For the syscall-based fcntl implementation use FcntlSyscall from
      internal/syscall/unix in order to get fcntl64 on 32-bit Linux
      systems.
      
      On aix, fcntl with F_DUPFD_CLOEXEC is not supported. Thus, defined
      F_DUPFD_CLOEXEC = 0 in the syscall package and check its value before
      calling fcntl(fd, syscall.F_DUPFD_CLOEXEC, 0).
      
      On js/wasm, fcntl is not supported thus let its implementation return
      ENOSYS directly.
      
      Updates #36211
      
      Change-Id: I96a2ea79e5c4eed2fefd94d0aefd72c940825682
      Reviewed-on: https://go-review.googlesource.com/c/go/+/212278
      Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
      TryBot-Result: Gobot Gobot <gobot@golang.org>
      Reviewed-by: default avatarIan Lance Taylor <iant@golang.org>
      bbd25d26
  6. 30 Dec, 2019 3 commits
  7. 27 Dec, 2019 2 commits